Programming the FM 452
6.10

Parameter Transfer Routes

The term parameter includes the following machine and cam data.
PG/PC
offline
Download
10
Para. ass.
user interface
11
Upload to PG
1
4
HW Config
2
System data
(SDB)
Figure 6-1
Parameter Transfer Routes
1
Save parameters in the parameter assignment user interface.
2
Save HW configuration, compile, and download to CPU.
3
The CPU writes the parameters to the module during system parameter assignment.
4
Upload the parameters of the module to the PG with the "Upload" command.
5
Download parameters from FM Config to the module with the "Download" command.
6
Write parameters to the module using jobs in the user program.
7
Read parameters from the module using jobs in the user program.
8
Store parameters from the user program in the online DB.
9
Read parameters into the user program from the online DB.
10
Export parameters from the parameter assignment user interface to the DB (offline or online DB);
an offline DB must then also be downloaded to the CPU.
11
Import parameters from an online or offline DB into the parameter assignment user interface.
6-22
10b
DB
DB
10a
11a
11b
6
7
2a
System data
(SDB)
Download
CPU
online
8
User
program
9
CAM_CTRL
5
3
FM 452 Electronic Cam Controller
FM 452
Parameters
(machine and
cam data)