Summary of Contents for Siemens SIMATIC FM 455 C

  • Page 1 ______________ Introduction SIMATIC FM 455 C ______________ Preparations ______________ Learning units SIMATIC ______________ Further Information FM 455 C Getting Started 02/2006 A5E00059365-03...
  • Page 2 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 3: Table Of Contents

    Table of contents Introduction............................. 1-1 Preparations ............................2-1 Learning units ............................3-1 Installing the configuration package ..................3-1 FM 455 C, installing and wiring....................3-1 Preparations for programming ....................3-3 Programming the analog input parameters ................3-4 Programming the error signal parameter................... 3-4 Programming the controller parameters ..................
  • Page 4 Table of contents FM 455 C Getting Started, 02/2006, A5E00059365-03...
  • Page 5: Introduction

    Introduction Purpose of this documentation Based on a practical example, this manual leads you through the various steps in commissioning a fully functional application, and thus introduces the basic functions of FM 455 C hardware and software, and corresponding test features. The references to the manual should give you an initial overview of the information it contains.
  • Page 6 Introduction FM 455 C Getting Started, 02/2006, A5E00059365-03...
  • Page 7: Preparations

    Preparations Requirements Hardware and software requirements: • An S7-400 station, consisting of a power supply module and a CPU. • STEP 7 (≥V4.02) is properly installed on your PG. • You have configured a project for the S7-400 station. • The PG is connected to the CPU. •...
  • Page 8 Preparations FM 455 C Getting Started, 02/2006, A5E00059365-03...
  • Page 9: Learning Units

    Learning units Installing the configuration package Procedure The configuration package contains a configuration tool for FM 455 C, all function blocks (FBs) you need to integrate your FM in the CPU user program, and various example programs. To install the software, place the CD into your drive, and then run SETUP.EXE from this CD. FM 455 Controller Module, Follow the setup instructions (see the manual, chapter...
  • Page 10 Learning units 3.2 FM 455 C, installing and wiring Insert the wired front connectors into the FM 455 C. Make sure they engage with an audible click. FM 455 C Getting Started, 02/2006, A5E00059365-03...
  • Page 11: Preparations For Programming

    Learning units 3.3 Preparations for programming Preparations for programming Procedure Controller Module FM 455 1. Open your project in SIMATIC Manager (see the manual, chapter "Assigning parameters to FM 455".) 2. Open the "HW Config" configuration table In your project. 3.
  • Page 12: Programming The Analog Input Parameters

    Learning units 3.4 Programming the analog input parameters Programming the analog input parameters Procedure In the first step, select a sensor type to enable the module to process an analog input and the corresponding controller. 1. Click of analog input 1. –...
  • Page 13: Programming The Controller Parameters

    Learning units 3.6 Programming the controller parameters Programming the controller parameters Procedure Click Control algorithm to view all optional settings. The selection returns a fuzzy temperature control and a PID control option. PID action control is set by default. Do not change this setting, and then close the "Controller 1" dialog box.
  • Page 14: Programming The Analog Output Parameters

    Learning units 3.8 Programming the analog output parameters Programming the analog output parameters Procedure Click to define the signal to output at analog output 1: Do not modify the default Manipulated value A, Controller 1. Click to select the type of signal (actuator type) for the analog output 1. Do not change the 0 ...
  • Page 15: Integrating Fm 455 C In The User Program

    Learning units 3.10 Integrating FM 455 C in the user program 3.10 Integrating FM 455 C in the user program 3.10 Procedure 1. In SIMATIC Manager, select File > Open... > Libraries to open the FM_PID library. 2. Copy FB 31 PID_FM from the FM 355, 455 PID Control / blocks container of the FM_PID library to the "Blocks"...
  • Page 16: Download Finished Example Program "Simatic 400 Station2 (C)

    Learning units 3.12 Download finished example program "SIMATIC 400 Station2 (C)" 3.12 Download finished example program "SIMATIC 400 Station2 (C)" 3.12 Procedure We recommend you use the example "SIMATIC 400 Station2 (C)" of the FM_PIDEx project for the next tests. As a result you can try out the FM 455 C on a simulated control section FM 455 Controller Module without using real processes (refer to the manual, chapter...
  • Page 17: Pid Controller Tuning

    Learning units 3.14 PID controller tuning 3.14 PID controller tuning 3.14 Procedure 1. Open online in the parameterization interface with Test > Controller optimization of the instance DB 31 of the example program. 2. Follow the instructions in the "Controller optimization" message windows: 3.
  • Page 18 Learning units 3.14 PID controller tuning FM 455 C 3-10 Getting Started, 02/2006, A5E00059365-03...
  • Page 19: Further Information

    Further Information Tuning temperature controllers Information Controller Module FM 455 For further information, refer to the manual, chapter "Parameter optimization at a temperature controller" and to the Online Help. Diagnostics Error diagnostics Errors may occur due to faulty parameters, incorrect wiring, or transducer failure. FM 455 C indicates such errors at the EXTF LED.
  • Page 20 Further Information 4.3 Examples FM 455 C Getting Started, 02/2006, A5E00059365-03...