Electronic cam controller installation and parameter assignment
Table of Contents

Advertisement

Create data blocks using the UDTs in the block folder of your S7 program. If
you use several modules, you require a separate set of data blocks for each
module.
Enter the module address in the channel DB and, if used in the diagnostic DB,
also at the address MOD_ADDR. You can also have the address entered
automatically by selecting the module in HW Config and then selecting a data
block in the "Properties" dialog with the "Mod Addr" button.
If your programming device/PC is connected to a CPU, you can now download
the FCs and DBs to the CPU.
FM 452 Electronic Cam Controller
C79000-G7076-C452-04
Programming the FM 452
6-3