10.2
Initiators
Initiators are simple switches without direction information that output pulses. You
specify the direction with the machine data for selecting the initiator.
Caution
!
Damage to equipment is possible.
Specifying a direction incorrectly can lead to serious errors in the system (for
example as a result of incorrectly activating units.
Check the direction information each time you install and start up a system and
whenever you replace an initiator.
Connectable Initiators
You can connect the following initiators to the FM 452:
Initiators with 24 V level (Proximity Switches)
Limit Frequency = 50 kHz
max. 100 m cable length
Signal Evaluation
With an initiator, the rising edge of Signal A* is counted.