Levelflex M FMP43
Suitability for hygenic
processes
Pharma (CoC)
Overfill prevention
Telecommunications
External standards and
guidelines
Endress+Hauser
Overview of permitted process connections, → ä 27.
Note!
The gap-free connections can be cleaned without residue using the usual cleaning methods.
Many versions of the Levelflex M meet the requirements of 3A-Sanitary Standard No. 74. Endress+Hauser
confirms this by attaching the 3A symbol.
Certificate of Compliance (CoC)
• See "Ordering information", → ä 42, feature 100 "Additional Option:", option"P".
• Materials in Contact with process made of 316L with Δ ferrite < 3%
• Surface roughness Ra < 0,38 μm/15 μin
• Information on ASME BPE Conformity
SIL 2, for 4 to 20 mA output signal (see SD00174F/00/EN "Functional Safety Manual").
Complies with "Part 15" of the FCC rules for an "Unintentional Radiator". All probes meet the requirements
for a "Class A Digital Device".
In addition, all probes in metallic tanks meet the requirements for a "Class B Digital Device".
The European directives and standards applied can be taken from the associated EC Declarations of
Conformity. In addition, the following also applied for Levelflex M:
EN 60529
Protection class of housing (IP-code)
NAMUR - international user association of automation technology in process industries.
• NE21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
• NE43
Standardization of the signal level for the failure information of digital transmitters.
74 -
74 -