To test run machine:
1.
Read and follow safety instructions at begin-
ning of manual, take all required safety pre-
cautions, and make sure all previous setup/
assembly steps in this manual have been
followed and completed.
2.
Clear all setup tools and loose items away
from machine.
3.
Make sure machine is disconnected from
power source.
4.
Remove chip collection tray and add 6.5
gallons of water to coolant reservoir (see
Figure 20). DO NOT run machine without
coolant in reservoir or coolant pump will be
damaged.
Note: For the Test Run, there is no need to
mix cutting fluid with the water.
Add Water Here
Figure 20. Coolant reservoir opening.
5.
Push Emergency Stop button (C).
6.
Connect machine to power source.
7.
Turn master power switch ON. Power lamp
(B) on control panel should illuminate to indi-
cate power is connected.
Note: Master power switch is located on
electrical panel access door, just below con-
trol panel (see Figure 2 on Page 4).
-22-
8.
Figure 21. Resetting Emergency Stop button.
9.
10. Turn operation mode switch (G) to manual
11. Check function of headstock hydraulics and
Chip
Collection
Tray
12. Check function of vise hydraulics by pressing
Twist Emergency Stop button (C) clockwise
until it pops out (see Figure 21). This resets
button so machine will start.
Push hydraulic pump button
should hear hydraulic pump (located in
machine base) turn ON.
mode
.
3-phase power supply polarity by using raise
headstock button
(L) and lower headstock
button
(J) to raise and lower headstock.
— If headstock raises when raise headstock
button
(L) is pushed and lowers when
lower headstock button
then phase polarity is correct. Remove
related shipping tag from control panel
and continue to Step 12.
— If headstock does not raise or lower when
raise headstock button
headstock button
power phase polarity is not correct. Push
Emergency Stop button (C), disconnect
machine from power source, switch any
two of three power supply wires on plug
or hardwired connection, then restart Test
Run.
vise open button
button
(K).
Model G0886 (Mfd. Since 01/19)
(C). You
(J) is pushed,
(L) and lower
(J) are pushed, then
(I) and vise close