Parameter Assignment - Siemens PPU 26x.3 series Manual

Ppu and components
Table of Contents

Advertisement

Switch S1, S2
Table 7-25
Setting of switch S1 as delivered
1
2
3
OFF
OFF
OFF
The two switches S1-9 and S1-10 must remain set to "ON".
The switches S1-1 to S1-8 define the PROFINET address. For a SINUMERIK 828D, the address "64" must always be assigned
to the MCP.
Table 7-26
Switch S1 settings
1
2
3
OFF
OFF
OFF
Further information on the addressing can be found in Section Addressing components
(Page 239).
The handwheel signal type is set with switch S2-1.
Table 7-27
OFF
Note
Switch S2-2 is reserved for test purposes.
7.3.3

Parameter assignment

The specifications for assigning input and output bytes listed in the tables are defined as
standard addresses in the PLC. Information on settings in the machine data can be found in
Section Activating components (Page 238).
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3
4
5
6
OFF
OFF
OFF
4
5
6
OFF
OFF
OFF
Switch S2 settings
1
Meaning
ON
differential interface
TTL interface
7
8
9
ON
OFF
OFF
7
8
9
ON
ON
OFF
Connectable components
7.3 MCP Interface PN
10
Meaning
ON
PLC I/O Interface
PROFINET address "0"
10
Meaning
ON
PROFINET address "64"