7.5.5

Technical data

MCP 310C PN
Parameter
Input voltage
Power consumption, max.
● Board
● Illumination
● Handwheels
● Total
Vibratory load:
● Operation
● Transport (in transport packaging)
Shock load:
● Operation
● Transport (in transport packaging)
Protection class acc. to EN 61800-5-1
Degree of protection acc. to DIN IEC 529
Condensation, spraying water, and icing
Relative humidity:
● Storage
● Transport
● Operation
Supply air
Cooling
Ambient temperature:
● Storage
● Transport (in transport packaging)
● Operation
Dimensions:
● Width
● Height
● Depth
Weight, approx.
Approvals
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3
Front
Rear
Connectable components
Value
24 V DC
5 W
43.2 W (6 x 7.2 W) *)
2 x 0.9 W
50 W
10 – 58 Hz: 0.15 mm
58 – 200 Hz: 2 g (acc. to EN 60068-2-6 test Fc)
5 – 9 Hz: 3.5 mm
9 – 200 Hz: 1 g (acc. to EN 60068-2-6)
15 g, 11 ms, 18 shocks according to EN 60068-1
15 g, 11 ms, 18 shocks according to EN 60068-2-27
III (DVC A, PELV)
IP54 (front)
IP00 (rear)
Not permitted
5 ... 95 %
5 ... 95 %
5 ... 95 %
Without aggressive gases, dusts, and oils
By natural convection
-25 °C ... 55 °C
-40 °C ... 70 ºC
0 ... 45 ºC
0 ... 55 °C
310 mm
175 mm
55 mm
1.2 kg
CE, cULus
7.5 MCP 310C PN
177