②After entering the main menu interface select "Actuator" , then enter the
sub-menu press the up and down keys to select " Gasoline nozzle (Current) ",
press "OK" button, after confirmation, before entering oscilloscope operation
interface, it will prompt "must comply with the current clamp using " Wait a few
seconds to enter the oscilloscope interface
③Connect current clamp to CH1,since the "Gasoline nozzle (Current)" Function of
oscilloscope has default settings (Probe 1X,time base 1ms),simply connect the
probe to the corresponding signal can display waveform.
④Press"CH1",can view the values and configuration(configuration has default)
⑤Waveform display can be adjusted based on their own through the vertical volts /
division and trigger ways to meet your needs(Time base, vertical volts / division
and other specific operations, please refer to the operation of general oscilloscope)
4)Gasoline nozzle (Voltage and Current)
①Same as Electromagnetic valve step 1
②After entering the main menu interface select "Actuator", then enter the
sub-menu press the up and down keys to select " Gasoline nozzle (Voltage and
Current) ",press "OK" button, after confirmation, before entering oscilloscope
operation interface, it will prompt " CH1:using probe,CH2:using current clamp"
Wait a few seconds to enter the oscilloscope interface
③Connect the probe to CH1 and probe set to 10X,then connect grounding clip to
the signal ground or grounding. Connect the current clamp to CH2
④Since the "Gasoline nozzle (Voltage and Current)" of oscilloscope has default
settings ( CH1:Probe 10X , time base 1ms; CH2: Probe 1X , time base
1ms) ,simply connect the probe to the corresponding signal can display waveform,
as picture 13
⑤Press"CH1" and "CH2", can view the values and configuration (configuration has
default)
⑥Waveform display can be adjusted based on their own through the vertical volts
/ division and trigger ways to meet your needs(Time base, vertical volts / division
and other specific operations, please refer to the operation of general
oscilloscope)
Voltage
Pic-13 Gasoline nozzle (Voltage and Current)
Current
21