User manual JINHAN JDS2012Q

Advertisement

Table of Contents
loading

Summary of Contents for Jinhan JDS2012Q

  • Page 1 User manual JINHAN JDS2012Q...
  • Page 2: Table Of Contents

    Exterior: ..........................3 Main interface: ........................4 ignition: ..........................4 sensor: ..........................6 Actuator: ........................... 7 bus: ............................ 8 Auto repair kit: ........................ 10 Load test: ......................... 11 Oscilloscope: ........................12 Channel 1: ....................... 13 TRIG: ........................14 HORI ........................15 Ruler: ........................
  • Page 3: Exterior

    Exterior:...
  • Page 4: Main Interface

    Main interface: Boot into the main interface, you can use different functions through each submenu. ignition: The main function of the ignition menu is to help customers quickly set the commonly used ignition signal parameters of the oscilloscope. Button function under ignition menu: determine ↑↓...
  • Page 5 At this time, press the OK key again to enter the waveform test (you can also press the return key to return to the previous menu) Routine 2 (use of current clamp): Select primary ignition (current), OK key to confirm after entering the oscilloscope: Note: At this time, the relevant parameter values of the oscilloscope interface have been adjusted to the current unit A, and all current parameters can be read directly.
  • Page 6: Sensor

    sensor: The main function of the sensor menu is to help customers quickly set the commonly used sensor signal parameters of the oscilloscope. Button function under sensor menu: determine ↑↓ Select function return Return to the previous menu Routine: Select the sliding resistance type of the accelerator pedal, after the OK button is confirmed, there will be corresponding notices: Note: This is a single-channel device, and the accelerator pedal is a two-wire output.
  • Page 7: Actuator

    Actuator: The main function of the actuator menu is to help customers quickly set the commonly used actuator signal parameters of the oscilloscope. Button function under the actuator menu: determine ↑↓ Select function Return Return to the previous menu Routine: Select the solenoid valve, after the OK button is confirmed, there will be corresponding notices:...
  • Page 8: Bus

    At this time, press the OK key again to enter the waveform test (you can also press the return key to return to the previous menu) bus: The main function of the bus menu is to help customers quickly set the commonly used bus signal parameters of the oscilloscope.
  • Page 9 ↑↓ Select function return Return to the previous menu Routine: After selecting the can bus and OK button to confirm, there will be corresponding notices: Note: This is a single-channel device, and the accelerator pedal is a two-wire output. To observe the two-wire, you need to use 2022Q.
  • Page 10: Auto Repair Kit

    Auto repair kit: The main function of the car kit menu is to help customers quickly set the relevant parameters of the oscilloscope when using the specified accessories. Button functions under the car kit menu: determine ↑↓ Select function return Return to the previous menu Routine: Select the engine cylinder pressure and confirm with the OK button, there will be corresponding...
  • Page 11: Load Test

    At this time, press the OK key again to enter the waveform test (you can also press the return key to return to the previous menu) Note: At this time, the relevant parameter values of the oscilloscope interface have been adjusted to the pressure unit Bar, and all pressure parameters can be directly read.
  • Page 12: Oscilloscope

    Use the multimeter pen to carry the positive and negative ends of the power cord. If the power supply meets the current responsible demand, the buzzer will beep for a long time and the green text will be displayed at the same time. If the power supply cannot meet the current demand, the buzzer will alarm and flash red letters.
  • Page 13: Channel 1

    The function buttons of the oscilloscope are classified as follows: Channel 1: Press the channel 1 button to enter the channel menu. Under the channel 1 button, the function keys have the following functions: Channel 1 display switch Unit number x1, x10, x100 selection AC/DC coupling options Save reference waveform when reference waveform A and B are open ←...
  • Page 14: Trig

    Under the channel 1 button, the function keys have the following functions: Channel 1 unit selection (voltage, current, pressure) invalid invalid Save reference waveform when reference waveform A and B are open ← CH1 mobile → CH1 mobile ↑ CH1 Gear adjustment ↓...
  • Page 15: Hori

    Select automatic trigger, normal trigger or single trigger Save reference waveform when reference waveform A and B are open ← Trigger movement (when smart trigger is off) → Trigger movement (when smart trigger is off) ↑ invalid ↓ invalid HORI Press the time base key to enter the following menu: Under the time base menu, the function keys have the following functions: Whether the ruler is displayed...
  • Page 16: Menu

    The upper foot of the interface will display the parameters of scale 1, 2 Under the time base menu, the function keys have the following functions: Whether the ruler is displayed The object of the ruler isCH1 The unit of the ruler (time, voltage or current or pressure) Save reference waveform when reference waveform A and B are open ←...
  • Page 17: Factory Reset And Self-Calibration

    Reference waveform saveCH1 Whether reference waveform A or B is open Save reference waveform when reference waveform A and B are open ← invalid → invalid ↑ invalid ↓ invalid Press the menu button for the second time to enter the following interface. Under the menu, the function key functions are as follows: Enter the factory reset menu CH1 Whether the waveform is inverted...
  • Page 18: Parameter Display

    Under the menu, the function key functions are as follows: invalid Self-calibration Confirm factory reset Save reference waveform when reference waveform A and B are open ← invalid → invalid ↑ invalid ↓ invalid (Note: Do not connect to any external equipment during self-calibration to ensure that the channel is disconnected!) Parameter display: Press the parameter key, the parameters of each channel will be displayed in the upper right...
  • Page 19: Multimeter

    Vmin Minimum voltage (will be displayed as the unit of the relevant channel changes, current, pressure) Vmax Maximum voltage (will be displayed as the unit of the relevant channel changes, current, pressure) Amplitude value (will be displayed as the unit of the relevant channel changes, current, pressure) Duty cycle multimeter:...
  • Page 20: Set Up

    Set up: Setting options description: Language Currently supports 5 languages (Chinese, English, Russian, Spanish, Portuguese) sound Choose to turn on or off the key sound Backlight Screen brightness adjustment 1-5 levels Smart trigger Turn smart trigger on or off Screenshot preview View the previous screenshot locally Waveform browsing View the previously saved waveform locally...
  • Page 21: Waveform Browsing

    Press and hold the parameter key for 2 seconds, you will hear 2 beeps, and the screenshot will start in the background. After the screenshot is completed, a dialog box for customizing the screenshot number will pop up. After editing the number (currently supports 0-7 up to 8 pictures), press ok to save. After the screenshot is completed, select the screenshot preview in the settings, and enter to see the current screenshot.
  • Page 22: Parameter Description

    After editing the number (currently supports up to 30 groups of waveforms from 0-29), press ok to save. After the waveform is saved, you can view the currently saved waveform in the set waveform browser. In this interface, you can see the preview of the saved waveform, and at the same time, you can choose to view the waveform with the OK key.
  • Page 23 Coupling DC, AC Display mode Input voltage 40V (Probex1); 400V(Probex10); Use high-voltage probes, the maximum voltage is determined by the quality of the probe. Time base range 12.5ns - 5s, 100ms - 5s, scan mode(scan) Storage depth Per channel 3K Trigger mode Automatic, normal and single Trigger type...