Technical data

14
Technical data
Performance data for alpha, version c
Type
Minimum
pump capacity
at maximum
back pressure
bar
l/h
50 Hz design
1001
10
0.9
1002
10
1.8
1004
10
3.5
1008
10
7.7
0707
7
6.9
0417
4
17.0
0230
2
29.7
60 Hz design
1001
10
1.1
1002
10
2.2
1004
10
4.1
1008
10
8.9
0707
7
8.3
0417
4
20.6
0230
2
34.4
*) Suction lift with unfilled dosing head, valves wetted.
42
Minimum
Stroke
pump capacity
rate
at medium
back pressure
bar
l/h
Stroke
s / min
5.0
1.0
30
5.0
2.1
58
5.0
3.9
58
5.0
8.6
128
3.0
7.7
58
2.0
18.3
128
1.0
32.7
128
5.0
1.3
36
5.0
2.6
69
5.0
4.7
69
5.0
10.4
154
3.0
9.2
69
2.0
21.9
154
1.0
39.2
154
Con‐
Suction
Pri‐
nector
lift*
ming
size
lift**
out‐
side Æ
x
inside
Æ
mm
m WS
m WS
6x4
5.0
2.6
6x4
5.0
3.6
8x5
5.0
3.6
8x5
5.0
3.6
8x5
4.0
4.1
8x5
4.0
4.1
12x9
3.0
3.1
6x4
5.0
2.6
6x4
5.0
3.6
8x5
5.0
3.6
8x5
5.0
3.6
8x5
4.0
4.1
8x5
4.0
4.1
12x9
3.0
3.1
Max‐
Max.
imum
permis‐
per‐
sible
mis‐
priming
sible
pres‐
starting
sure on
pres‐
the
sure
suction
side
bar
bar
10
5.0
10
5.0
10
5.0
10
5.0
7
3.5
4
2.0
2
1.0
10
5.0
10
5.0
10
5.0
7
5.0
7
3.5
2.5
2.0
1.5
1.0