Adapting to different types of gas

Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L & C
Front C
Rapid
Rear L
Front L Inner
Dual Burner
Front L Outer
Oven
Oven
downside
Broiler
Oven
upside
Models X365GGVX (X36 5 00 X)
Adapting to different types of gas
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L and R
Rapid
Rear L
Centre Inner
Dual Burner
Centre Outer
Oven
Oven
downside
Broiler
Oven
upside
CAUTION: save the orifices removed from the appliance for future use

REGULATION OF BURNERS

Primary air adjustment:
Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner:
1) Remove the oven bottom.
2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. 13) according to the measurements indicated in
table 4.
Broiler burner adjustment: to adjust the broiler burner loosen screw P and adjust the position X of the Venturi cone
(Fig. 14) according to the measurements indicated in table 4.
TABLE N°4: Burner primary air regulation (indicative)
Type of gas
Inches (mm)
NG (Natural Gas)
LP
(Propane Gas)
Injector
Gas
diam. [mm.]
Type
0,90
NG
0,54
LP (Propane)
1,18
NG
0,70
LP (Propane)
1,55
NG
0,92
LP (Propane)
0,80
NG
0,49
LP (Propane)
N°2 x 1,15
NG
N°2 x 0,70
LP (Propane)
2,00
NG
1,15
LP (Propane)
1,90
NG
1,10
LP (Propane)
Injector
Gas
diam. [mm.]
Type
0,90
NG
0,54
LP (Propane)
1,18
NG
0,70
LP (Propane)
1,55
NG
0,92
LP (Propane)
0,80
NG
0,49
LP (Propane)
N°2 x 1,15
NG
N°2 x 0,70
LP (Propane)
2,00
NG
1,15
LP (Propane)
1,90
NG
1,10
LP (Propane)
Burner
Oven
Broiler
Inches (mm)
9/16 (15)
fully open
fully open
fully open
Pressure
Max Rate
[i.w.c.]
[BTU/h]
[W]
4"
3400
996
11"
3400
996
4"
6100
1787
11"
6100
1787
4"
10400
3047
11"
10400
3047
4"
2800
820
11"
2800
820
4"
12000
3516
11"
12000
3516
4"
16000
4688
11"
16000
4688
4"
14500
4248
11"
14500
4248
[M3W0GTU4X(2 or 5)A]
Pressure
Max Rate
[i.w.c.]
[BTU/h]
[W]
4"
3400
996
11"
3400
996
4"
6100
1787
11"
6100
1787
4"
10400
3047
11"
10400
3047
4"
2800
820
11"
2800
820
4"
12000
3516
11"
12000
3516
4"
16000
4688
11"
16000
4688
4"
14500
4248
11"
14500
4248
11
Min Rate
By-pass
[BTU/h]
[W]
diam. [mm]
900
264
Regulated
900
264
1500
439
Regulated
1500
439
2500
732
Regulated
2500
732
900
264
Regulated
900
264
4500
1318
Regulated
4500
1318
4000
1172
Regulated
4000
1172
Only Max
Only Max
No by-pass
Only Max
Only Max
No by-pass
Min Rate
By-pass
[BTU/h]
[W]
diam. [mm]
900
264
Regulated
900
264
1500
439
Regulated
1500
439
2500
732
Regulated
2500
732
900
264
Regulated
900
264
4500
1318
Regulated
4500
1318
4000
1172
Regulated
4000
1172
Only Max
Only Max
No by-pass
Only Max
Only Max
No by-pass
0,29
0,36
0,47
0,29
0,65
0,60
0,29
0,36
0,47
0,29
0,65
0,60