Days Override (Do); Regeneration Time (Rt) - Pentair FLECK 5810 SXT Installer Manual

Hide thumbs Also See for FLECK 5810 SXT:
Table of Contents

Advertisement

Installer Manual Fleck 5810 - SXT - Programming

6.5.11. Days override (DO)

Set the maximum number of days between regeneration cycles.
Note
This parameter allows to set the maximum amount of days that the system can stay in
service mode without a regeneration.
Mandatory
In time clock mode the setting of this parameter is mandatory.
Note
Setting the parameter to "OFF" disables this function.
Note
The number of days can be set from OFF, or 1 to 99 days.
Note
This parameter is not displayed for the day of week regeneration.
Y
Press
or
Z
Press
to validate the selection and move to the next parameter.

6.5.12. Regeneration time (RT)

Set the regeneration time.
Note
Regeneration time is the time of the day when regenerations occur for meter delayed
regeneration, time clock regeneration, day of the week regeneration and calendar override
regeneration.
AA Press
or
AB Press
to validate the selection and move to the next parameter.
64 / 106
to set the days override.
to set the regeneration time.
Ref. MKT-IM-016 / C - 08.06.2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents