Initial Start-up Step-by-step Instructions
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
4
Rev A
Step 1: Program System Size
This step may have been performed by your system's OEM manufacturer. In this
case, proceed to step 2.
Input system size - resin volume - in cubic feet or liters.
Use UP and DOWN buttons to scroll through resin volume choices.
Choose the nearest volume to your actual system size.
To choose a 3-cycle filter operation - press DOWN until an "F" is displayed.
Press SET to accept the system size you've selected.
If incorrect setting is programmed, see "Resetting the Control" section below.
Step 2: Program Time of Day
While "12:00" is blinking, set the correct time of day.
Use the UP and DOWN buttons to scroll to the correct time of day.
"PM" is indicated, "AM" is not indicated.
Press SET to accept the correct time of day and advance to the next
parameter.
Step 3: Set Day of Week
Press SET to make the arrow under SU flash.
Use the UP and DOWN buttons to advance the arrow until it is under the
correct day of week.
Press SET to accept and advance to the next parameter.
After steps 1-4, the controller will operate most systems. Proceed to step 5 if
further adjustments to your system's programming is needed.
To exit the programming state, wait 30 seconds and the controller will
automatically put you into the normal operating mode.
Step 4: Set Regen Time
2:00 (AM) is the default time of regeneration. To accept this time, press the
DOWN button to move to step 5.
To change the regen time, press SET - causing 2:00 to flash.
Use the UP and DOWN buttons to advance to the desired regen time.
Press SET to accept the time and advance to the next parameter.
Step 5: Set Days to Regenerate (740 Time-clock Control Only)
If using 760 control - proceed to step 5a.
Set number of days between time-clock regeneration (regen frequency).
Default time is 3 days.
Days can be adjusted from 1/2 (.5) to 99 days.
To change, press SET to make the "3" flash.
Use the UP and DOWN buttons to change to the number of days desired.
Press SET to accept the regen frequency, and advance to the next cycle.
To use the 7-day timer option - see full Dealer Installation Manual.
Step 5a: Set Calendar Override (760 Demand Control Only)
If using 740 control - proceed to step 7.
Set number of days for calendar override on demand control.
"0" days is the default for calendar override.
Days can be adjusted from 1/2 (.5) to 99 days.
To change, press SET to make the "0" flash.