Regenerant Line Connection - Autotrol Logix 740 Operation Manual

Control autotrol 255 and autotrol performa series valves (268, 268fa)
Table of Contents

Advertisement

Figure 9
Overflow Line Connection

Regenerant Line Connection

(not used with 3-cycle filter system)
Figure 10
Air Check for 255 valve
EQUIPMENT INSTALLATION
The regenerant line from the tank connects to the valve. Make the
connections and hand tighten. Be sure that the regenerant line is secure
and free from air leaks. Even a small leak may cause the regenerant line to
drain out, and the conditioner will not draw regenerant from the tank. This
may also introduce air into the valve causing problems with valve
operation.
Most installations utilize a tank check valve. This is not necessary when
using the 255 valve with the built-in aircheck. Using a tank check valve
with the 255 valve with aircheck will result in premature checking of the
aircheck valve, before the tank is empty.
Overflow Fitting
Drain Tubing
Secure hose in place
Air Gap
Drain
Regenerant Line Connection
19