SYSTEM DISINFECTION
Calcium Hypochlorite
Calcium hypochlorite, 70% available chlorine, is available in several forms
including tablets and granules. These solid materials may be used directly
without dissolving before use.
1. Dosage
A. Two grains (approximately 0.1 ounce [3 ml]) per cubic foot.
2. Regenerant tank conditioners
A. Backwash the conditioner and add the required amount of
hypochlorite to the well of the regenerant tank. The regenerant tank
should have water in it to permit the chlorine solution to be carried
into the conditioner.
B. Proceed with the normal regeneration.