Autotrol Logix 764 Operation Manual

Autotrol Logix 764 Operation Manual

For autotrol 255 series

Advertisement

O p e r a t i o n M a n u a l
Models: 255
Twin Alternating
Twin Parallel
Single with Remote
Regeneration Start
Multi-Single Tank with
Lockout
Logix 764

Advertisement

Table of Contents
loading

Summary of Contents for Autotrol Logix 764

  • Page 1 Logix 764 O p e r a t i o n M a n u a l Models: 255 Twin Alternating Twin Parallel Single with Remote Regeneration Start Multi-Single Tank with Lockout...
  • Page 2: Table Of Contents

    Table of Contents Safety Information ..........3 How To Use This Manual .
  • Page 3: Safety Information

    Safety Information • This water conditioner’s control valve conforms to UL/ Do not allow this water conditioning system to CE Standards. Generic valves were tested and certified freeze. Damage from freezing will void this water for compliance as verified by the agency listing. conditioning system’s warranty.
  • Page 4: How To Use This Manual

    Training in the 764 series control and the 255 valve. Note: Helpful hint to simplify procedure. • Knowledge of water conditioning and how to The Logix 764 control can be installed on several type determine proper control settings. valves that can have twin alternating, twin parallel or •...
  • Page 5 LCD Display SU MO TU WE TH FR SA Time/Day Regeneration Time Salt Amount Front Capacity x100 Hardness Lbs/ft³ Down Button Manual Regen Button No-Salt Detector Set Button Up Button (Chlorine Generator) AC Adapter Connection (low voltage) Multi Single Tank Input Back Lockout &...
  • Page 6 Location Selection Location of a water conditioning system is important. The following conditions are required: • Level platform or floor. • Room to access equipment for maintenance and adding regenerant (salt) to tank. • Ambient temperatures over 34 F (1 C) and below F (49 •...
  • Page 7: Outdoor Locations

    Outdoor Locations When the water conditioning system is installed outdoors, several items must be considered. • Moisture – The valve and control are designed for use in NEMA 3 locations. Falling water should not affect performance. The system is not designed to withstand extreme humidity or water spray from below.
  • Page 8 Unconditioned water in Conditioned water out Figure 6 Typical Plumbing for Twin Tank Systems. Unit in Service Unit in Bypass Figure 7...
  • Page 9: Location Selection

    Installation All plumbing must conform to local codes. The two flowing from a heat source to the conditioners is to tanks should be plumbed to an interconnecting install an expandable accumulator tank before the hot manifold, Figure-6. It is highly recommended that water heater.
  • Page 10: Brine Line Connection

    of the loop is level with the drain line connection. This will provide an adequate siphon trap.Where a drain empties into an overhead sewer line, a sink-type trap must be used. Secure the end of the drain line to prevent it from moving (Figure-11). Brine Line Connection It is recommended that separate brine lines be used for each tank.
  • Page 11: Electrical Connection

    Electrical Connection Caution: This valve and control are for dry location use only unless used with a Listed Class 2 power supply suitable for outdoor use. The 764 Series control operates on a 12-volt alternating current power supply. This requires use of the Pentair Water supplied AC adapter.
  • Page 12: Disinfection Of Water Conditioning Systems

    Disinfection of Water Conditioning Systems The materials of construction in the modern water Calcium Hypochlorite conditioning system will not support bacterial growth, Calcium hypochlorite, 70% available chlorine, is nor will these materials contaminate a water supply. available in several forms including tablets and During normal use, a conditioner may become fouled granules.
  • Page 13: System Operation

    System Operation Treated Water (Downflow) Repressurization – Cycle C4 Untreated water is conditioned as it flows through Pressure is balanced in the valve before continuing the resin bed and up the riser. the regeneration. Backwash (Upflow) – Cycle C1 Fast Rinse (Downflow) - Cycle C5 Flow is reversed by the control valve, directed Water passes through the resin bed and up down the riser, up through the resin bed and sent...
  • Page 14: Camshaft Cycle Positions

    Camshaft Cycle Positions Valve Disc Location/Function The front end of the camshaft has an indicator cup. The 6 Backwash/Drain cup has slots in the outer edge and cycle numbers on 5 Rinse Drain the inside face (Figure-12). Wiring Remove the cover and look over the top of the 764 Breakouts control to view the cycle numbers.
  • Page 15: Display Icons & Cursors

    Display Icons & Cursors WE TH FR SA DAYS SU MO TU Time/Day Regeneration Time Salt Amount If your Logix 764 controller was purchased as a filter control, the overlay will show: Time/Day, Capacity x100 Backwash Time, Backwash Length Hardness and Capacity.
  • Page 16: Keypad - Buttons

    24. Cycle (C). The number displayed by #23 is the P r o g r a m m i n g C o n v e n t i o n s current cycle in the regeneration sequence. The 700 series controller is programmed using the 25.
  • Page 17: Placing Water Conditioning System Into Operation

    When water flows steady from the faucet, the they differ from previous valve instructions. tank(s) are purged. Note: All Logix 764 controls will be shipped in the 4. Turn off the faucet then turn off the incoming water service (treated water) position. Do not rotate the supply.
  • Page 18 These cam movements may take up to 5 minutes. T a b l e 2 Resin Volume - 0.25 ft and 5 Liter Steps Resin Volume Tank Dia Injector Metric (inches) 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00...
  • Page 19: Level L Programming - 764 Control With 255 Valve, 8 Cycle Conditioner

    Level l Programming - 764 Control with 255 Valve, 8 Cycle Conditioner Screen Buttons to Description Range Press SU MO TU WE TH FR SA DAYS Time/Day Regeneration Time Cubic feet: 0.25 then Resin Volume Salt Amount Select correct resin volume press Capacity 3.00...
  • Page 20: Quick Cycling The Control 255L And 255P

    255 Alternating and parallel tank systems have one A. Quick cycle the control to the C2 regenerant Logix 764 control that is mounted on tank 1. Tank 2 has draw/slow rinse position . a blank faceplate and the valve is controlled by the Logix 764 control on tank 1.
  • Page 21: Quick Cycling The Control For 255A Systems

    10. Finally, turn on a faucet plumbed after the water conditioner. Run the faucet until the water runs clear. 255 Alternating tank systems have one Logix 764 control that is mounted on tank 1. Tank 2 has a blank 11. Add the appropriate amount of regenerant to faceplate and the tank 2 valve is controlled by the Logix regenerant tank.
  • Page 22 Tank 2 moves through cycles: 4. Turn on a faucet plumbed after the water conditioner. Run the faucet until the water runs C1 - Backwash clear. As water enters the tank, air will be forced out 5. Add water to the regenerant tanks. the drain line.
  • Page 23: In Service Display

    • Time of Day: Includes PM indicator. Can be set to Note: The faucet icon is displayed on all the Logix 764 display as a 24-hour clock. See Level ll controls when there is flow. The 764 will show the...
  • Page 24: Level Ii Programming - P Values

    Depends on value entered in P16 (not used for Capacity alternating mode) 0 = internal magnum NHWB, 1, 6 = 1" Autotrol turbine 2, 7 = 2" Autotrol turbine 3 = User defined K-factor Flow sensor select 4 = User defined Pulse Equivalent 5 = Internal Magnum HWB Values 6 &...
  • Page 25: Programming The Lockout Feature

    Programming the Lockout Feature All Level I parameters can be locked out when the control is in Level ll programming. Simply press the REGEN button during Level ll programming and a Lock Icon will appear indicating that the specific setting has been locked out.
  • Page 26 Salt Setting The default P6 salt setting is set at 9 lbs/cu ft. Under normal circumstances this setting will provide the correct system capacity. This setting may be adjusted to change the exchange capacity. T a b l e 4 E x c h a n g e C a p a c i t y 2 5 5 V a l v e Exchange Exchange...
  • Page 27: Level Lll Cycle Programming - C Values

    Level lll Cycle Programming – C Values Several Level III program parameters can be adjusted to fine-tune a valve operation for non-standard Note: The control must by in the treated water position applications. Typically these parameters will not need to to change settings.
  • Page 28: Level Iv Viewing History - H Values

    Level IV Viewing History - H Values Historical information can be viewed by pressing the SET and DOWN buttons simultaneously, with the 764 control in the home position. Release both buttons when the control displays an “H” value. Press the UP or DOWN buttons to navigate to each setting.
  • Page 29: Program Reset

    Program Reset The 764 control can be reset to original factory parameters when viewing the H0 parameter. Press and hold the SET button for three seconds while H0 is displayed. Release the button. All settings except for Time of Day and Day of Week will be reset. The 764 Logix control will now display the valve and system type.
  • Page 30: Manual Regeneration Options

    Manual Regeneration Options Refill First Option Double Immediate Manual Regeneration Refill First is only available for single tank “L” and twin Back-to-Back manual regenerations are initiated by parallel “P” models. pressing and holding the REGEN button for three seconds while the control is in the regenerating mode. The 764 control allows users to select when the refill A solid x2 icon next to the regeneration icon will appear cycle occurs.
  • Page 31: Regeneration Modes For Parallel Systems

    Regeneration Modes for Parallel Systems Parameter P16 is used to determine the method for demand initiated regeneration. Four regeneration modes are possible. • P16 = 0, Delayed Regeneration with a Smart T a b l e 7 T P 1 6 = 0 Reserve Regenerations will start only at the Time of Flow Continuous...
  • Page 32: Wiring Diagrams

    Wiring Diagrams Connecting the Logix 764 Twin Alternating or Parallel Controls The twin sensor and extension cables are used for twin unit parallel and alternating applications. Four standard connections are required for operation; the power transformer, the flow sensor, motor/optical sensor, and the connection between tank 1 and tank 2 controls.
  • Page 33 Connecting the Logix 764 Multi Single Tank Control Logix 764 control on Tank 1 Repeat for all remaining tanks Logix 764 control Logix 764 control on Tank 2 on Tank 3 Note: Cable PN 3020228 sold separately. Figure 17...
  • Page 34: Parts Lists

    Parts Lists 255 Exploded View & Parts List...
  • Page 35 Part Part Item Description Qty. Item Description Qty. Number 3014650 764 Series Control 1000269 Injector Cap with O-Ring 0.33 Refill Ball & Cone Type Flow 1244650 Valve Assembly w/o Flow Controls 1243511 Controller 1235340 Top Plate Air Check Kit 1234170 Screw, Top Plate 1032416 3/8 –inch male 1235341...
  • Page 36: Bypass Valve And Turbine Adapter

    Bypass Valve and Turbine Adapter Bypass Inlet Drain Outlet Turbine Adapter Part Item Description Qty. 1040769 256 Bypass 1034301 Kit, 256 Rotor Replacement 1034302 Kit, 256 Rotor Seals (2), O-Rings (4), Clips (2) 1032347 Assy, Adapter 1-inch Turbine included with 255A, P and L valves N o t S h o w n...
  • Page 37: Manifold Kits

    Manifold Kits Part Part Description Qty. Description Qty. 3019931 255 Manifold Kit, 1-in, PVC w/256 Bypass 3019932 764 Manifold Kit, 1-in PVC w/No Bypass Kit Includes: Kit Includes: Pipe Fitting, Tee, 1-in Pipe Fitting, Tee, 1-in Pipe Fitting, Elbow, Sch 40, 1-in, PVC Pipe Fitting, Elbow, Sch 40, 1-in, PVC Pipe Fitting, Sch 40, 1-in, Str Elbow, PVC Pipe Fitting, Sch 40, 1-in, Str Elbow, PVC...
  • Page 38: Troubleshooting

    Troubleshooting 764 Controller – Error Codes & 255 ”L” with Check Salt Light Problem Possible Cause Solution ERR 1 is displayed. Program settings have been corrupted. Press any key and reprogram Level I settings. Controller on tank 1 does not know the Wait for two minutes for the controller to return to position of the camshaft.
  • Page 39 System Troubleshooting Problem Possible Cause Solution a. Uncontrolled refill flow rate. a. Remove refill flow control to clean ball and seat. b. Air Leak in regenerant line to air b. Check all connections in regenerant line check. for leaks. Regenerant tank overflow. c.
  • Page 40 2008 Pentair Residential Filtration, LLC © P/N 3019624 Rev B...