Regeneration Modes

SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
x2
Capacity
C
Hardness
Total regen time remaining
DISPLAY ICONS 700 CONTROLLER
"Duration" describes how long a button is held down:
P/R for press and release
HOLD for press and hold
X sec for a number of seconds to press the button and hold it
down
"Display" calls out the display icons that are visible.
The 700 Series controllers can be regenerated either automatically or
manually. During a regeneration, the total time remaining of the
regeneration will be displayed on the controller. The current cycle is shown
in the lower left of the display.
To Initiate a Manual Regeneration:
Press REGEN once for delayed regeneration. System will regenerate at
next set regen time (2:00 AM).
A flashing regen (recycle) symbol will be displayed.
Press and hold REGEN for 5 seconds to initiate immediate manual
regeneration. A solid regen symbol will be displayed.
After immediate regeneration has begun, press REGEN again to
initiate a second manual regeneration. A flashing "x2" symbol
indicates the second regeneration will start at the time of
regeneration. Press and hold REGEN to turn on the second
regeneration immediately following the current regeneration. The
double regeneration is indicated by the "x2" symbol being on steady.
During a Regeneration:
A "C#" is displayed to show current cycle.
MIN
Total regen time remaining is displayed on screen.
Press and hold SET to show current cycle time remaining.
To Advance Regeneration Cycles:
Press and hold SET - showing current cycle time.
Simultaneously press SET and UP to advance on cycle. An hourglass
will display while cam is advancing.
When cam reaches next cycle, "C2" will be displayed.
Repeat SET and UP to advance through each cycle.
Press and hold SET and UP for 5 seconds to cancel regen.
Hourglass will flash once cancelled.
Camshaft will advance to home – may take 1 to 2 minutes.