Autotrol 255-960 Operation And Maintenance Manual

Autotrol 255-960 Operation And Maintenance Manual

Water conditioning control system for 255 series valve

Advertisement

Series 255 Valve / 960 Control
®
Water Conditioning Control System
Operation and Maintenance Manual

Advertisement

Table of Contents
loading

Summary of Contents for Autotrol 255-960

  • Page 1 Series 255 Valve / 960 Control ® Water Conditioning Control System Operation and Maintenance Manual...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Table of Contents Table of Contents Introduction ......3 Special Features .
  • Page 3: Introduction

    • Introduction Introduction Introduction Introduction Hardness and Capacity Settings. Once the hardness and capacity settings are entered, the The Model 960 control provides sophisticated, information cannot be lost due to a power outage, demand-based water conditioning by incorporating a so reprogramming is not necessary. microprocessor and a water meter to electronically •...
  • Page 4: Control Settings

    The front panel incorporates several important features To change a setting: Press the down arrow [↓] button which allow you to know the status of your water until the green light is illuminated next to the control conditioner. These features are: setting you want to change.
  • Page 5: Time Of Regeneration

    next number starts flashing. You can only change 5. Press the SET button. The number stops flashing the flashing number. and the control accepts the new setting. After approximately 30 seconds, the control starts 4. Continue changing numbers until you reach the alternating the display between TIME OF DAY and desired setting.
  • Page 6: Salt Setting

    Salt Setting next number starts flashing. You can only change the flashing number. The Salt Setting refers to the total amount of salt, in 4. Continue changing numbers until you reach the pounds, that the control uses during a regeneration of desired setting.
  • Page 7: Water Conditioner Regeneration

    Complete the following steps to change the Capacity available for use, and the control starts alternating the Setting; refer to Table 1: display between TIME OF DAY and CAPACITY. No settings can be changed during a regeneration. The 1. Press the down arrow [↓] button until the green light settings can be viewed, but the control beeps and next to the CAPACITY legend is on.
  • Page 9: Manual Valve Operation

    Be sure that the drain line remains unrestricted so that Calendar Override regeneration water and brine can flow freely to the The Calendar Override option is a method of forcing the drain. Do not set objects on the drain line that could control to regenerate after a preset number of days, if a crimp the line and restrict flow.
  • Page 11 Valve Body and Tank Adapter Module Valve Body and Tank Adapter Module Valve Body and Tank Adapter Module Valve Body and Tank Adapter Module Part Part Code Description Qty. Code Description Qty. 1000238 Valve Assembly w/o Flow Controls Injector Cap with O-Ring: 1000824 Camshaft, Standard, One-Piece 1000217...
  • Page 12 Meter Adapter, Bypass Valve and Piping Boss Meter Adapter, Bypass Valve and Piping Boss Meter Adapter, Bypass Valve and Piping Boss Meter Adapter, Bypass Valve and Piping Boss Bypass Valve Piping Boss Inlet 960 Control Drain Outlet Meter Adapter Wall-Mount Transformer Inlet Drain Outlet...
  • Page 13 Meter Adapter, Bypass Valve and Piping Boss Meter Adapter, Bypass Valve and Piping Boss Meter Adapter, Bypass Valve and Piping Boss Meter Adapter, Bypass Valve and Piping Boss Part Part Code Description Qty. Code Description Qty. Bypass Valve Bypass Valve Bypass Valve Bypass Valve Piping Boss...
  • Page 15: Troubleshooting Procedures

    Table 3 Troubleshooting Procedures Problem Cause Solution Hard Water at the Tap. a. Low or no salt in the salt storage tank. a. Refill the salt storage tank and manually initiate a regeneration. Refer to the b. Salt setting too low to accommodate Manual Regeneration section in this water hardness or water usage.
  • Page 16 Table 3 Troubleshooting Procedures Problem Cause Solution Intermittent or irregular brine a. Low water pressure. a. Increase water pressure. draw. b. Defective injector ! b. Replace both injector and injector cap. Contact dealer. Brine tank overflow. a. Brine valve disc 1 held open. a.
  • Page 17: Specifications

    Specifications Specifications Specifications Specifications Voltage..............102 to 132 VAC, 60 Hz Current.
  • Page 18 © Copyright 2000, 1999 Osmonics Printed in the USA P/N 1017934 Rev. C...