Autotrol Logix 740 Operation Manual page 23

Control autotrol 255 and autotrol performa series valves (268, 268fa)
Table of Contents

Advertisement

Valve Disc Operation
Figure 14 - 255 Valve
Figure 15 - Performa Valve (263, 268)
EQUIPMENT INSTALLATION
Regeneration Cycle Indicators
C0 = Treated Water - normal operation mode
C1 = Backwash Cycle
C2 = Regenerant Draw Cycle (not used in filter mode)
C3 = Slow Rinse Cycle (not used in filter mode)
C4 = System Pause
C5 = Fast Rinse Cycle 1
C6 = Backwash Cycle 2 (not used in filter mode)
C7 = Fast Rinse Cycle 2 (not used in filter mode)
C8 = Regenerant Refill (not used in filter mode)
6 Backwash/Drain
5 Rinse Drain
4 Outlet Valve
2 Bypass Valve
3 Outlet
2 Inlet
1 Regenerant
6 Rinse Drain
3 Inlet Valve
5 Refill Valve
1 Regenerant Valve
4 Bypass
7 Backwash Drain Valves
23
Rev A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logix 760

Table of Contents