Autotrol Logix 740 Operation Manual page 34

Control autotrol 255 and autotrol performa series valves (268, 268fa)
Table of Contents

Advertisement

SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Standard Setting
Capacity
SU MO TU
WE TH FR SA DAYS
Hardness
Time & Day
Regen Time & Day
Salt Amount
Capacity
Hardness
High Capacity Setting
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt Amount
Capacity
Hardness
Low Setting (High Efficiency)
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt Amount
Capacity
Hardness
34
Rev A
After steps 1-4, the controller will operate most systems. Proceed to
step 4 if further adjustments to your system's programming is needed.
Step 4: Set Regen Time
2:00 (AM) is the default time of regeneration. To accept this time, press
the DOWN button to move to step 5.
To change the regen time, press SET – causing "2:00" to flash.
Use the UP and DOWN buttons to advance to the desired regen time.
Press SET to accept the time and advance to the next parameter.
Step 5: Set Days to Regenerate (740 Time-Clock Control Only)
If using 760 control – proceed to step 5a.
Set number of days between time-clock regeneration (regen
frequency).
Default time is 3 days.
Days can be adjusted from ½ (.5) to 99 days.
To change, press SET to make the "3" flash.
Use the UP and DOWN buttons to change the number of days desired.
Press SET to accept the regen frequency, and advance to the next
cycle.
To use the 7-day timer option –see Dealer Installation Manual.
Step 5a: Set Calendar Override (760 Demand Control Only)
If using 740 control – proceed to step 6.
Set number of days for calendar override on demand control.
"0" days is the default for calendar override.
Days can be adjusted from ½ (.5) to 99 days.
To change, press SET to make the "0" flash.
Use the UP and DOWN buttons to change to the number of days
desired. Press SET to accept the regen frequency, and advance to the
next cycle.
Step 6: Amount of Regenerant used per Regeneration
Set desired regenerant amount.
Default setting is "S" standard salting.
3 salt settings are available on 740 and 760 controls:
S – Standard Salt – 9 lbs/cubic foot of resin (120 grams/liter of resin)
H – High Salt – 15 lbs/cubic foot of resin (200 grams/liter of resin)
L – Low Salt – 3 lbs/cubic foot of resin (40 grams/liter of resin)
Low Salt is the "Highly Efficient Mode".