Multiport Flow Selector
January 2019

Installation

Minimum Tools Required
A torque wrench, socket wrench, and Allen head wrenches are required to install the Multiport Flow Selector Valve and
actuator assembly.
Table 4. Socket Size for Multiport Bonnet Studs and Nuts
VALVE SIZE, NPS
2 x 4
3 x 6
4 x 8
4 x 10
6 x 16
Other socket sizes (inch) required: 7/16, 1/2, 9/16, 3/4, 7/8, and 1-1/8.
Allen key sizes (inch) required: 5/32, and 1/4
Table 5. Wrench Sizes (Inch) for Multiport Inlet and Outlet Flanges
FLANGE SIZE, NPS
CL150
2
- - -
3
1-1/16
4
- - -
6
1-1/4
8
- - -
10
- - -
16
- - -
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury. Check with your process or safety engineer for any additional measures that must be taken to protect against
process media.
Avoid personal injury and property damage by keeping hands, tools, and other objects away from the plug while operating
the valve.
Observe all WARNING decals and tags.
4
ASME CLASS RATING
SOCKET SIZE (in)
CL300
CL600
CL900
CL150
CL300
CL600
CL900
CL1500
CL300
CL600
CL900
CL1500
CL300
CL600
CL900
CL1500
CL2500
CL300
1-1/16
1-1/4
1-1/4
1-1/4
1-7/16
- - -
2
1-5/8
2
2-3/8
2-3/16
2-3/4
2-9/16
3-1/8
3-7/8
5
ASME CLASS RATING
CL600
CL900
1-1/16
1-7/16
1-1/4
1-7/16
1-7/16
1-13/16
1-5/8
1-13/16
1-13/16
2-3/16
- - -
- - -
2-3/8
2-9/16
Instruction Manual
CL1500
CL2500
- - -
- - -
1-13/16
- - -
2
- - -
2-3/16
1-13/16
- - -
- - -
2-15/16
- - -
3-7/8
3-1/2