Table 6. Bonnet Bolting Torque
VALVE SIZE,
NPS
2 x 4
3 x 6
4 x 8
4 x 10
6 x 16

Plug Seal Adjustment

1. Prior to adjusting the seal assembly (key 12 and 13), align the plug (key 2) with an open inlet port and insert the
supplied adjustment tool. Once this tool has been secured to the seal adjuster (key 18), rotate this tool counter
clockwise until the scraper (key 10) touches the inside surface of the body (key 1). The resistance to rotate the
adjustment tool will increase once the scraper contacts the body. Remove the adjustment tool.
2. Rotate the plug (key 2) a few revolutions to check for binding or excessive turning torque. If the plug rotates
smoothly, then insert, secure, and rotate the adjustment tool counter clockwise to tighten the seal adjuster (key
18) to the appropriate torque value listed in table 7.
Note
Do not exceed the torque values listed in table 7. Exceeding these values may cause the valve to not function as intended.
Table 7. Plug Seal Torque
VALVE SIZE, NPS
2 x 4
3 x 6
4 x 8
4 x 10
6 x 16
10
ASME
CLASS RATING
mm
300
25.4
600
900
150
300
31.8
600
900
1500
38.1
300
34.9
600
900
1500
44.5
300
41.3
600
900
50.8
1500
63.5
2500
82.6
ASME CLASS RATING
300
600
900
150
300
600
900
1500
300
600
900
1500
300
600
900
1500
2500
STUD SIZE
Inch
1
1-1/4
1-1/2
1-3/8
1-3/4
1-5/8
2
2-1/2
3-1/4
TORQUE
N•m
ft•lbs
41
30
48
35
41
30
54
40
54
40
95
70
Instruction Manual
D104239X012
TORQUE
N•m
ft•lbf
217
160
441
325
814
600
651
480
1356
1000
1085
800
2034
1500
4203
3100
10170
7500