Introduction

Scope of Manual

This instruction manual includes installation,
maintenance, and parts information for the Design
NotchFlor DST control valve. Refer to separate
manuals for instructions covering the actuator,
positioner, and accessories.
No person may install, operate, or maintain Design
NotchFlo DST valves without first D being fully
trained and qualified in valve, actuator, and
accessory installation, operation, and maintenance,
and D carefully reading and understanding the
contents of this manual. If you have any questions
about these instructions, contact your Fisher sales
office before proceeding.
Neither Emerson, Emerson Process
Management, nor Fisher assume
responsibility for the selection, use, or
maintenance of any product.
Responsibility for proper selection,
use, and maintenance of any Fisher
product remains solely with the
purchaser.
www.Fisher.com
r
DST Control Valve
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
Note
1
1
1
3
3
4
4
6
7
9
10
10
11
12
13
13
W9050
Figure 1. Design NotchFlo

Description

The Design NotchFlo DST globe (figure 1) and angle
valves have metal seats, cage guiding, quick change
trim, and push-down-to-close valve plug action.
Class 600 (all valve sizes) and Class 900 and 1500
(2- to 4-inch valves) use balanced valve plugs. Class
900 and 1500 (1- and 1.5 valves) use an unbalanced
valve plug. To provide a seal between the cage and
a balanced valve plug, the balanced valve plugs use
a pressure-assisted spring-loaded seal ring.
Design NotchFlo DST Valves with 3-stage and
4-stage anti-cavitation trim (figure 2) offer control of
high pressure drop liquids while avoiding the
damaging effects of cavitation in a properly sized
valve.
NotchFlo DST control valves utilize a high
resistance, multi-stage, axial flow process where
fluid flow is parallel to the axis of the plug and cage.
Pressure reduction occurs throughout the length of
the plug; thus individual stages aren't exposed to the
full pressure differential. Therefore, trim life is
enhanced.
NotchFlo DST
r
DST Control Valve

Advertisement

Table of Contents
loading

Summary of Contents for Emerson FISHER NotchFlo DST

  • Page 1: Table Of Contents

    Note valve. Neither Emerson, Emerson Process NotchFlo DST control valves utilize a high Management, nor Fisher assume resistance, multi-stage, axial flow process where responsibility for the selection, use, or fluid flow is parallel to the axis of the plug and cage.
  • Page 2 Instruction Manual Form 5794 NotchFlo DST February 2005 Table 1. Specifications Available Valves Shutoff Classification –12 Class V: [5x10 /sec/bar/mm of port diameter Class 600 3-Stage: Level C only (0.0005 mL/min/psid/in) of water at service Class 900 and 1500 4-Stage: Levels A, B, pressure drop] per ANSI/FCI 70-2 and IEC and C 60534-4...
  • Page 3: Specifications

    Instruction Manual Form 5794 NotchFlo DST February 2005 If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this instruction manual. WARNING Some bonnet flanges have a tapped hole that was used to handle the bonnet during manufacture.
  • Page 4: Maintenance

    Instruction Manual Form 5794 NotchFlo DST February 2005 D The valve packing box may WARNING contain process fluids that are pressurized, even when the valve has been removed from the pipeline. Personal injury could result from Process fluids may spray out under packing leakage.
  • Page 5 Instruction Manual Form 5794 NotchFlo DST February 2005 UPPER WIPER UPPER WIPER (KEY 27) (KEY 27) PACKING PACKING FOLLOWER FOLLOWER (KEY 28) (KEY 28) FEMALE FEMALE ADAPTOR ADAPTOR PACKING PACKING RING RING MALE MALE WASHER ADAPTOR ADAPTOR SPACER (KEY 24) (KEY 25) SPRING (KEY 24)
  • Page 6: Adding Packing Rings

    Instruction Manual Form 5794 NotchFlo DST February 2005 Table 3. Class 600 Recommended Torque for Packing Flange Nuts (non live-loaded) GRAPHITE TYPE PACKING PTFE TYPE PACKING VALVE STEM VALVE STEM DIAMETER Minimum Torque Maximum Torque Minimum Torque Maximum Torque CLASS CLASS Inches LbfSin...
  • Page 7: Replacing Packing

    Instruction Manual Form 5794 NotchFlo DST February 2005 Table 5. Torque for Body-to-Bonnet Bolting Using Nickel Never-Seez Lubricant for Class 600 NotchFlo DST Valves BOLT TORQUES VALVE VALVE VALVE SIZE VALVE SIZE, SA193-B7, SA193-B8M Class 2 SA193-B8M Class 1 RATING RATING INCHES INCHES...
  • Page 8 Instruction Manual Form 5794 NotchFlo DST February 2005 Table 7. Valve Stem Connection Torque and Hole Size for Pin VALVE STEM DIAMETER TORQUE, MINIMUM TO MAXIMUM HOLE SIZE Inches LbfSft Inch 12.7 81-115 60-85 3.20 - 3.25 0.126 - 0.128 19.1 0.75 237-339...
  • Page 9: Trim Removal

    Instruction Manual Form 5794 NotchFlo DST February 2005 nominal value. Apply the final torque value again and, if any nut still turns, tighten every nut again. VALVE STEM Note PACKING FOLLOWER When installing packing rings, prevent BONNET entrapping air between the rings. Add the rings one at a time without forcing TOP OF PACKING RING EVEN WITH...
  • Page 10: Valve Plug Maintenance

    Instruction Manual Form 5794 NotchFlo DST February 2005 2. Lift the valve stem and attached valve plug out of the pin hole through the stem. Refer to table 7 for the valve body. If the valve plug is to be reused, tape drill sizes.
  • Page 11: Trim Replacement

    Instruction Manual Form 5794 NotchFlo DST February 2005 For a Design NotchFlo DST unbalanced valve, 1. Install the seat ring gasket (key 12) into the valve install the valve plug and stem assembly (keys 5 body. Install the seat ring (key 4). and 6) into the cage.
  • Page 12: Parts Ordering

    Retorque the packing flange nuts as required. See Note tables 3 and 4. Neither Emerson, Emerson Process Management, nor Fisher assume responsibility for the selection, use, or maintenance of any product. Parts Ordering...
  • Page 13: Parts Kits

    Instruction Manual Form 5794 NotchFlo DST February 2005 Parts Kits Packing Kits (non live-loaded) Stem Diameter, mm (Inches) 12.7 (0.5) 19.1 (0.75) 25.4 (1) Yoke Boss Diameter, mm (Inches) 71 (2.8125) 90 (3.5625) 127 (5) Single PTFE (Contains keys 22, 24, 25, 26, 27) RPACKX00022 RPACKX00032 - - -...
  • Page 14 Instruction Manual Form 5794 NotchFlo DST February 2005 j APPLY LUB GE14588-A Figure 7. Design NotchFlo DST Class 600 Balanced Globe Valve Assembly (size 1 to 3 inch)
  • Page 15 Instruction Manual Form 5794 NotchFlo DST February 2005 j APPLY LUB GE14589 Figure 8. Design NotchFlo DST Class 600 Balanced Globe Valve Assembly (size 4 inch)
  • Page 16 Instruction Manual Form 5794 NotchFlo DST February 2005 j APPLY LUB GE09701-A Figure 9. Design NotchFlo DST Class 1500 Balanced Globe Valve Assembly (size 2 and 3 inch)
  • Page 17 Instruction Manual Form 5794 NotchFlo DST February 2005 j APPLY LUB GE14166-A Figure 10. Design NotchFlo DST Class 1500 Balanced Globe Valve Assembly (size 4 inch)
  • Page 18 Instruction Manual Form 5794 NotchFlo DST February 2005 j APPLY LUB GE14052-A Figure 11. Design NotchFlo DST Class 1500 Unbalanced Angle Valve Assembly (size 1 to 1.5 inch)
  • Page 19 Instruction Manual Form 5794 NotchFlo DST February 2005 j APPLY LUB GE11286-A Figure 12. Design NotchFlo DST Class 1500 Balanced Angle Valve Assembly (size 2 and 3 inch)
  • Page 20 NotchFlo and Fisher are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners.

Table of Contents