Alarm connections

You can select how the VIP X1600 module responds to an alarm. In the event of
an alarm, the unit can automatically connect to a predefined IP address. You can
enter up to 10 IP addresses which the VIP X1600 module will contact in order in
the event of an alarm, until a connection is made.
Connect on alarm:
Select On so that the VIP X1600 module automatically connects to a predefined
IP address in the event of an alarm.
By setting Follows input 1 the unit maintains the connection that has been auto-
matically established for as long as an alarm exists on alarm input 1.
Note
Stream 2 is always transmitted for alarm connections. Bear this fact in
mind when assigning the profile (see page 42).
Number of destination IP address:
Specify the numbers of the IP addresses to be contacted in the event of an
alarm. The unit contacts the remote stations one after the other in the numbered
sequence until a connection is made.
Destination IP address:
For each number enter the corresponding IP address for the desired remote sta-
tion.