EN | 99
Digital I/O
In the event of an alarm, the alarm LED of the triggering alarm input lights up in
green next to the video image. The unit's configuration determines whether the
alarm is displayed, as well as additional details (see Livepage configuration,
page 87).
The alarm icons Input 1 ... Input 4 are for information purposes and indicate the
status of an alarm input: Active high = icon lit green, Active low = icon not lit.
Trigger relay
You can switch connected units by means of the relays in the VIP X1600 mod-
ules (for example lights or door openers).
– To activate this, click the icon for the corresponding relay next to the video
image. The icon will be red when the relay is activated.
System log / Event log
The System log field contains information about the operating status of the unit
and the connection. You can save these messages automatically in a file
(see page 89).
Events such as the triggering or end of alarms are shown in the Event log field.
You can save these messages automatically in a file (see page 89).