Pro-Cut PFM 9.2 DRO Technical Manual page 51

Table of Contents

Advertisement

G2X CALIBRATION
CONTINUED
CALIBRATION STEP 3:
With the display in 'H' mode, and the 0.800" / 20.32mm thick calibration block in place, press the CALI-
BRATION button, the same one used to set the LRO Acceptance number. You will hear a beep. When you
have done this, you can press the Reset button to exit the H mode or use the Start button again if you wish
to read the DRO numbers out or switch between inch and mm display mode.
CALIBRATION STEP 4:
The cutting head and slide sensor are now calibrated to read thickness correctly. To check calibration you
can put the gage block between the inserts again and re-tighten. If you read between 0.796" / 20.22mm
and 0.804" / 20.42mm you are properly calibrated.
USING THE G2X
If you rotate the adjustment knobs, you will see the DRO display transition to thickness display. After 8
seconds of inactivity the display will alternate between the thickness reading and whatever else had been
on screen. Operation of the DRO remains unchanged. You turn on the motor and press the Start button.
WWW.PROCUTUSA.COM
PG /
Ø51