34

Flow chart for schedule setting

• Schedule setting
Schedule
mode
setting
: select the
schedule mode
NOTE
!
• If you press
configured condition and it exits from schedule setting mode.
Press
button shortly.
Entry to schedule setting mode.
Select day of week
Press
Schedule number
selection
Press
Schedule
AM/PM setting
Press
Schedule time setting
Press
Schedule minute
setting
Press
Schedule
temperature setting
Press
Schedule setting finish
button, the schedule setting condition is changed back to previously
: select the day of
week to set up the
schedule.
button.
: select schedule
number to set up
schedule (1~8)
button.
: select AM or PM
button.
: select the schedule
hour (1~12, 1 Hour
interval)
button.
: select the schedule
minute (00~50,
10 minutes interval)
button.
: select the schedule
temperature (18~30°C)
It is possible operation
mode of cooling, heating
and auto only.
button.