  • Page 1 Installation and operating instructions CPX37xx-0010 Multi-touch Panel PC for use in hazardous locations, zone 2/22 Version: Date: 2018-05-09...
  • Page 3: Table Of Contents

    Table of Contents Table of Contents 1 Notes on the documentation ........................ 5 Explanation of symbols........................ 6 Documentation issue status ...................... 7 2 For your safety............................ 8 Intended use ............................ 8 Notes about operation in potentially explsive areas ................ 9 2.2.1 Special conditions (ATEX) .................... 9 2.2.2 Special conditions (IECEx) ....................
  • Page 4 Table of Contents 10.2 Approvals for USA and Canada ...................... 37 10.3 Connection Kits/ Connecting Cables/ Accessories................ 38 10.4 Support and Service ........................ 39 Version: 0.1 CPX37xx-0010...
  • Page 5: Notes On The Documentation

    EP0851348, US6167425 with corresponding applications or registrations in various other countries. ® EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany Copyright © Beckhoff Automation GmbH & Co. KG, Germany. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited.
  • Page 6: Explanation Of Symbols

    Notes on the documentation Explanation of symbols The following symbols with corresponding warnings or explanatory text are used in the documentation. Read and follow the warnings. Symbols that warn of personal injury: DANGER Serious risk of injury Note this warning. Hazard with high risk of death or serious injury. WARNING Risk of injury Note this warning.
  • Page 7: Documentation Issue Status

    Notes on the documentation Documentation issue status Version Comment Preliminary Version CPX37xx-0010 Version: 0.1...
  • Page 8: For Your Safety

    Beckhoff Automation GmbH & Co. In addition, the following actions are excluded from the liability of Beckhoff Automation GmbH & Co. KG: • Failure to comply with this documentation.
  • Page 9: Notes About Operation In Potentially Explsive Areas

    The connectors on the backside of the Panel PC must be protected against mechanical damage either with Beckhoff mounting arm adapter C9900-M763 or on site by customer installation. The protective cap of the USB socket (X102, X103) must be fully tightened to meet the IP65 rating.
  • Page 10: Special Conditions (Iecex)

    The connectors on the backside of the Panel PC must be protected against mechanical damage either with Beckhoff mounting arm adapter C9900-M763 or on site by customer installation. The protective cap of the USB socket (X102, X103) must be fully tightened to meet the IP65 rating.
  • Page 11: Marking

    For your safety 2.2.3 Marking The Panel PC CPX37xx-0010 bears a The Panel PC CPX37xx-0010 is continuous serial number, markings certified for potentially explosive areas and a production date on the name and bears the following: plate: ATEX: DEKRA 18ATEX0053 X II 3G Ex nA IIC T5 Gc II 3D Ex tc IIIC T100°C Dc IECEx:...
  • Page 12: Safety Instructions

    • The sensitivity of an Panel PC against malicious software increases with the number of installed and active software. • Uninstall or disable unnecessary software. Further information about the safe handling of networks and software can be found in the Beckhoff Information System: http://infosys.beckhoff.com...
  • Page 13: Staff Qualification

    For your safety Staff qualification All operations involving Beckhoff software and hardware may only be carried out by qualified personnel with knowledge of control and automation engineering. The qualified personnel must have knowledge of the administration of the Panel PC and the associated network.
  • Page 14: Transport And Storage

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. Version: 0.1 CPX37xx-0010...
  • Page 15: Product Overview

    The mounting arm Panel PC is suitable for use in hazardous locations, zone 2/22. The CPX37xx combine reliable Beckhoff Control Panel design with state-of-the-art Industrial PC technology. The right display size is available for every application. With their highly integrated 3½-inch motherboards, the CPX37xx Panel PCs represent a high-performance platform for machine...
  • Page 16: Access To The Interfaces

    Product overview Access to the interfaces The interface of the Panel PC are located at the back side of the housing and at the side. Fig. 1: Connection block of the Panel PC CPX37xx-0010 with all interfaces Fig. 2: CFast card slot and battery of the system clock behind the cover plate Version: 0.1 CPX37xx-0010...
  • Page 17: Name Plate

    Product overview Name plate The Panel PC CPX37xx-0010 bears a The Panel PC CPX37xx-0010 is continuous serial number, markings certified for potentially explosive areas and a production date on the name and bears the following: plate: ATEX: DEKRA 18ATEX0053 X II 3G Ex nA IIC T5 Gc II 3D Ex tc IIIC T100°C Dc IECEx:...
  • Page 18: Description Of The Interfaces

    Product overview Description of the interfaces Interface Power supply (X101) LAN1 (X104) LAN2 (X105) optional USB output (X102-X103) Also see about this 2 Ground [} 19] 4.3.1 Power supply (X101) Conductive cross-section The connector is specified for 7.5 A and can lift conductive cross-sections of 1.5 mm The power supply for the Panel-PC is established via the socket X101.
  • Page 19: Lan1, Lan2 (X104, X105)

    Product overview 4.3.2 LAN1, LAN2 (X104, X105) X104, X105 Connection via standard-RJ45-cabel The RJ-45 connectors (X104, X105) allow the PC to be connected to a 100/1000 BASE-T Local Area Network (LAN). The standard configuration is only with one LAN Port X104. Optional a second LAN port X105 is available.
  • Page 20: Access To The Battery And The Cfast Card Slot

    Product overview 4.3.5 Access to the battery and the CFast card slot The battery and the CFast card slot are located behind a cover plate at the side of the Panel PC. After removing the screws with a star screwdriver Torx size 10 the cover plate can be taken off. Version: 0.1 CPX37xx-0010...
  • Page 21 Product overview Removing the cover plate allows access to the CFast card slot and the battery. WARNING Danger of Explosion! Replace battery only with the identical type or an alternative type recommended by the manufacturer. Notice correct polarity! CPX37xx-0010 Version: 0.1...
  • Page 22: Mounting And Wiring

    Mounting and wiring Mounting and wiring Mounting The Panel PC CPX37xx is designed for industrial application in machine and plant engineering. The Panel PC is intended for mounting arm installation either via 100 x 100 mm mounting interface or optional available mounting arm adapter for mounting arm systems with 48 mm tube (C9900-M763).
  • Page 23 Mounting and wiring Earthing measures Earthing connections dissipate interference from external power supply cables, signal cables or cables to peripheral equipment. Establish a low-impedance connection from the earthing point on the Panel PC housing to the central earthing point on the control cabinet wall, in which the Panel PC is being installed. Malfunction possible with missing ground connection A proper ground connection of the device is absolutely necessary for the correct function of the touchscreen.
  • Page 24: Mounting The Mounting Arm Tube

    Mounting and wiring 5.1.2 Mounting the mounting arm tube After feeding the connection cables of the Panel PC thought the mounting arm tube (1), the mounting arm tube will be positioned into the mounting arm adapter. Also the mounting arm tube is locked by tightening the Allen screw in the region of the socket (3) with a 3 mm Allen key.
  • Page 25 Mounting and wiring NOTE Tolerance of the mounting arm tube diameter The mounting arm tube must have a diameter of 48 mm with a maximum tolerance of -0.1 mm/ +0.8 mm. CPX37xx-0010 Version: 0.1...
  • Page 26: Wiring

    Mounting and wiring Wiring 5.2.1 Preparation and protective earthing NOTE The mains plug must be disconnected Please read the documentation for the external devices prior to connecting them! During thunderstorms, plug connector must neither be inserted nor removed! When disconnecting a plug connector, always handle it at the plug.
  • Page 27: Connecting

    Mounting and wiring 5.2.2 Connecting NOTE Use the correct fuse The power supply must be protected with maximum 4 A. Cable Cross Sections For the connection of the power supply, wiring with a cable-cross-section of 0.5 … 1.5 mm² must be used. With bigger distances between voltage source and PC, you take the voltage drop as a function of the cable- cross-section as well as voltage fluctuations of your distribution voltage into account, so that is secured that the voltage doesn't fall under 22 V at the power supply.
  • Page 28: Fitting The Power Supply

    Mounting and wiring 5.2.3 Fitting the power supply Version: 0.1 CPX37xx-0010...
  • Page 29: Operation

    Operation Operation Switching the Panel PC on and off Switching on The Panel PC does not have its own mains power switch. As soon as the power supply is switched on the Panel PC is activated. Shutting down and switching off Control software such as is typically used on Industrial PCs permits various users to be given different rights.
  • Page 30: Servicing And Maintenance

    Maintenance The Panel PC is maintenance-free. Do not open the Panel PC. For hardware problems, please contact the Beckhoff Service Emergency procedures In case of fire, the Panel PC should be extinguished with powder or nitrogen.
  • Page 31: Troubleshooting

    No power supply to the Panel PC/ Check power supply cable Industrial PC 1. Correctly connect cable 2. Call Beckhoff Service Cable not connected Computer boots, software starts, but Cause of the fault is either in the Call the manufacturer of the...
  • Page 32: Assembly Dimensions

    Assembly dimensions Assembly dimensions CPX3715-0010 Version: 0.1 CPX37xx-0010...
  • Page 33 Assembly dimensions CPX3719-0010 CPX37xx-0010 Version: 0.1...
  • Page 34 Assembly dimensions CPX3721-0010 Version: 0.1 CPX37xx-0010...
  • Page 35: Technical Data

    Technical Data Technical Data Product name CPX3715-0010 CPX3719-0010 CPX3721-0010 Dimensions (W x H x D) 375 x 290.9 x 70 445.1 x 364.8 x 70 549.8 x 330.3 x 70 Weight approx. 6.9 kg approx. 9 kg approx. 9.6 kg Supply voltage 24 V DC (22 –...
  • Page 36: Appendix

    Appendix Appendix 10.1 Standards reference for explosive atmospheres The following standards have been used: ATEX Standard Description EN 60079-0:2012+A11:2013 Explosive atmospheres - Part 0: Equipment - General requirements EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection “n” EN 60079-31:2014 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"...
  • Page 37: Approvals For Usa And Canada

    Appendix 10.2 Approvals for USA and Canada FCC: Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 38: Connection Kits/ Connecting Cables/ Accessories

    Appendix 10.3 Connection Kits/ Connecting Cables/ Accessories One 4-pole power supply connector is provided with the Panel PC. Optionally prefabricated connection cables for the network connection are available. Connecting ca- Network cable with IP65 connector bles C9900-K281 network cable for CP32xx, CP37xx, CPX37xx and CP72xx, length 3 m, assembled, Harting push-pull Ethernet connector IP 65, second end RJ45, IP 20 C9900-K282...
  • Page 39: Support And Service

    Beckhoff's branch offices and representatives Please contact your Beckhoff branch office or representative for local support and service on Beckhoff products! The addresses of Beckhoff's branch offices and representatives round the world can be found on her internet pages: http://www.beckhoff.com You will also find further documentation for Beckhoff components there.