Kalor Ada 28B User Manual page 7

Boiler stove
Table of Contents

Advertisement

PARAMETER
Heat input
Nominal heat output
Reduced heat output
Water heat output
Reduced water heat output
CO concentration at nominal reference (13% O
CO concentration at reduced reference (13% O
Nominal efficiency
Reduced efficiency
Pellet consumption (min-max)
Heated surface
Flue gas flow rate (min-max)
Draft (min-max)
Flue gas temperature (min-max)
Thermostove water
DHW flow rate
Maximum working pressure
Tank capacity
Smoke outlet tube
Diameter air intake
Connecting heating
Connecting health
Nominal voltage
Nominal frequency
Power consumption max
Thermostove weight
IEE
N° Test Report
Ambiental decree n.186
Energetic class
Dust at 13% O2 at nominal heat output
M. UNITS
kW
kW
kW
kW
kW
)
mg/m
3
2
)
mg/m
3
2
%
%
Kg/h
1,113 - 4,028
mc
g/s
Pa
°C
litri
litres/minute
Bar
Kg
mm
mm
Inch
Inch
V
Hz
W
Kg
mg/m
3
NSAT200
NSAT240
19,03
23,12
18,22
21,96
5,08
5,08
13,98
17,86
4,20
4,20
54,9
55,9
356,6
356,6
95,74
94,98
96,71
96,71
1,113 - 4,893
350
400
4,5 - 10,1
4,5 - 12,9
5 - 10
5 - 10
62,1 - 99,1
62,1 - 109,2
50
50
7,8
9,44
2,5
2,5
42
42
80
80
50
50
3/4
3/4
1/2
1/2
230
230
50
50
400
400
230
230
131
130
K 1324 2014 T1
A ++
8,9
8,5
55

Hide quick links: