Kalor Ada 28B User Manual page 49

Boiler stove
Table of Contents

Advertisement

In the automatic
position the
thermostove always
runs at full power
The thermostove
starts up "alone"
The power does not
change even if you
manually adjust
Anomalies related to the plumbing circuit
PROBLEM
No increase in
temperature with
stove in operation
Condensation
in thermostove
Radiators cold
in winter but the
thermostove boils
Hot water in not
provided
The thermostove boils
under "modulation"
that reaches the
temperature set on
the thermostat of the
thermostove
1.
Room
thermostat
maximum
2. Temperature sensor defective
3. Control panel defective or
broken
1. Incorrect programming of the
cronothermostat
1. The board is set to automatic
correction of power in proportion
to the temperature
POSSIBLE CAUSE
1. Incorrect combustion
adjustment
2. Thermostove/system dirty
3. Insufficient stove power
1. Incorrect setting maximum
water temperature in the
thermostove
2. Insufficient fuel consumtion
1. Circulator does not run
because blocked
2. Radiators have air in them
1. Circulator pump blocked
1. It 'been set to a value of
thermostat too high
2. It was set too much power to
the implant.
set
to
1. Reset the thermostat temperature
2. Check the operation of the sensor and replace
if necessary
3. Check the panel and replace if necessary
1. Check the settings of the cronothermostat
1. Contact your Authorized Assistance Center
REMEDY
1. Check parameters
2. Check and clear the thermostove
3. Check that the stove is properly sized for the
requirements of the system
1. Set the stove to a higher temperature. The
maximum water temperature in the thermostove is
65 ° C and can not be set below 40 ° C or above 80
° C. It is advisable to never adjust the temperature
below 50/55 ° C to avoid condensation in the
thermostove.
Adjust the power of the pump at a higher
temperature to 50/55 ° C.
2. Contact your Authorized Assistance Center
1. Free up the circulator by removing the plug and
turning the shaft with a screwdriver.
Check the electrical connections of the same,
replace if necessary
2. Vent the radiators
1. Free the circulator pump
1. Lower the temperature in the thermostove
2. Reduce the value of operating power
97