Description Of Operator Panels; 1) Designation Of Operating Elements; 2) Feed Switch; 3) Hold Down Clamp Switch - BLUM MINIPRESS P Manual

Hide thumbs Also See for MINIPRESS P:
Table of Contents

Advertisement

2 - Description of operator panels

2.1 - Description of operator panels

2.1.1) Designation of operating elements

(2.1)
Main switch
(2.2)
Feed switch
(2.3)
Hold down clamp switch
(2.4)
Operating mode display switch
ATTENTION:
The main switch does not disconnect the assembly machine
from the air pressure system.
Pos.0: Operational status indicator
set-up mode
- Motor cannot be started
- Stroke movement can be carried out
Pos.1: Operational status indicator
tional mode
- Drilling and the fitting insertion can be carried out
- The marking line lights
ATTENTION:
For long durability of the laser the main switch should be set on
pos. 0 when not operating.
Main switch can be secured against unauthorized drilling using a standard padlock.

2.1.2) Feed switch

(2.2)
ATTENTION:
When pressing the feed switch, keep your hands away from the work
area (A) of the assembly machine.
Pressing the feed switch will carry out the currently selected
workprocess.
Set up:
+
Main switch at Pos.0 + feed switch pressed
Drill:
+
Main switch at Pos.1 + feed switch pressed
Insert fitting:
+
Swivel in swing arm + press feed switch

2.1.3) Hold down clamp switch

Option: Hold down clamps are not standard equipment.
Pos. Clamps on:
Pressing the feed switch
Briefly touching the hold down clamp switch
Pos. Clamps off:
Pressing and turning the clamp switch to Pos.
clamps. When the feed switch
engaged.
13
(2.4)
does not light. Assembly machine in
(2.4)
lights. Assembly machine is in opera-
(2.2)
(2.2)
automatically engages the hold down clamps.
(2.3)
will disengage the clamps.
will turn off the hold down
(2.2)
is pressed, the hold down clamps remain
BA-101/3EN M53.XXXX