PXW MODEL CONFIGURATION
P X W
Front panel size
1/16 DIN
1/8 DIN
72mm
1/4 DIN
Type of input
Thermocouple (°C)
Thermocouple (°F)
RTD/Pt100 (°C)
RTD/Pt100 (°F)
4-20mA DC, 1-5V DC
0-20mA DC, 0-5V DC
Control Output 1
Relay contact (reverse action)
Relay contact (direct action)
SSR/SSC driver (reverse action)
SSR/SSC driver (direct action)
4 to 20mA DC (reverse action)
4 to 20mA DC (direct action)
Control Output 2*
None
Relay contact (reverse action)
Relay contact (direct action)
SSR/SSC driver (reverse action)
SSR/SSC driver (direct action)
4 to 20mA DC (reverse action)
4 to 20mA DC (direct action)
*not available on PXW-4 type
Alarm Options
Heater break alarm*
Process alarm & Heater break alarm*
None
Process alarm
*not available on PXW-4, or with 4-20mA output
Power Supply Option
24V AC/DC
ACCESSORIES (Sockets: only for PXW4 and sold separately)
____________________________________________________
8-pin sockets
(for PXW-4 without H / L Alarm Option)
ATX1NS
Solder Type Socket
PG-08
Screw-down type (terminals on back)
ATX2PSB
Screw-down type (terminals on back) (UL)
TP28X
Screw-down type (terminals on front) (UL)
11-pin sockets
(for PXW-4 with H / L Alarm Option)
PG-11
Screw-down type (terminals on back)
TP311SB
Screw-down type (terminals on back) (UL)
TP311S
Screw-down type (terminals on front) (UL)
Heater Break Current Sensing Transformer:
CTL-6-SF
For heater current (1 to 30 amps)
CTL-12-S36-8F
For heater current (20 to 50 amps)
____________________________________________________
1
Code
4
5
7
9
Code
T
R
N
S
B
A
Code
A
B
C
D
E
F
Code
Y
A
B
C
D
E
F
Code
2
3
4
5
Code
D
PXW SPECIFICATIONS
V
INPUT RANGE TABLE:
________________________________________________________
Input Signal
________________________________________________________
Thermocouple
J
K
R
B
S
T
T
E
N
PL2
________________________________________________________
RTD
Pt100
________________________________________________________
DC Voltage/
Current
1-5V
0-5V
4-20mA
0-20mA
________________________________________________________
CONTROL FUNCTION
(SINGLE OUTPUT)
_________________________________________________________
Control action
_________________________________________________________
Proportional band (P)
_________________________________________________________
Integral time (I)
_________________________________________________________
Differential time (D)
_________________________________________________________
P,I,D = 0: 2-position action
I,D = 0: Proportional action
_________________________________________________________
Proportional cycle
_________________________________________________________
Hysteresis width
_________________________________________________________
Anti-reset wind up
_________________________________________________________
Input sampling cycle
_________________________________________________________
Control cycle
_________________________________________________________
CONTROL FUNCTION
(DUAL OUTPUT) (Heat/Cool Type)
_________________________________________________________
Heating Proportional band P x 1/2 (P= 0-999.9%)
_________________________________________________________
Cooling Proportional band Heating proportional band
_________________________________________________________
Integral time
_________________________________________________________
Differential time
_________________________________________________________
_________________________________________________________
P,I,D= 0: 2-position action (without dead band) for heating and cooling
I,D= 0: Proportional action
_________________________________________________________
Proportional cycle
_________________________________________________________
Hysteresis width
6
Input Range
Input Range
(°C)
(°F)
0~800
32~1472
0~1200
32~2192
0~1600
32~2912
0~1800
32~3272
0~1600
32~2912
-199~200
-328~392
-150~400
-238~752
-199~800
-328~1472
0~1300
32~2372
0~1300
32~2372
-150~850
-238~1562
Scaling Range: -1999 to 9999
Engineering Units
PID control with auto-tuning
Fuzzy control with auto-tuning
0-999.9%, of full scale (FS), setting in 0.1% steps
0-3200 sec, setting in 1 sec steps
0-999.9 sec, setting in 0.1 sec steps
1-150 sec, setting in 1 sec steps, for relay contact
output and SSR/SSC drive output only
0-50% FS, setting in 1 E.U. (Engineering Unit) steps,
2-position action only
0-100% FS, setting in 1 E.U. steps, auto-setting
with auto-tuning
0.5 sec
0.5 sec
x Cooling proportional band coefficient
Cooling proportional band coefficient= 0-100
0: 2-position action
0-3200 sec for heating and cooling
0-999.9 sec for heating and cooling
1-150 sec, for relay contact output and SSR/SSC
drive output only
2-position action for heating and cooling: 0.5% FS
2-position action for cooling: 0.5% FS
Remarks
Cold Junction
compensating
function built-in
Allowable wiring
resistance 10 ohms
max (per wire)
For current input, use
the 250Ω resistor
to obtain 1-5 V or
0-5V DC input

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxw series

Table of Contents