Meter repairs
T-Slot transducer assemblies are available on 4-inch and larger meters for Daniel 3410
Series Ultrasonic Gas Flow Meters. The T-Slot assemblies are available on all meter sizes for
the Daniel JuniorSonic
CAUTION!
LEAKAGE OR PRESSURE CONTAINING PARTS FAILURE
Use precautions to eliminate hazards to personnel in the event of leakage or failure of the liquid
ultrasonic meter pressure containing parts or failure of the test equipment and to prevent over-
pressurization during the test procedure.
Failure to comply may result in injury to personnel or cause damage to the equipment.
3.2.1

T-Slot Transducer assembly and mount

Figure 3-1:
A. Transducer mount
B. Captive screws
C. T-slot transducer holder
D. Cable nut
E. Chordset
Procedure
1.
2.
3.
44
Meters (Models 3412 and 3411).
T-slot transducer mount and holder
Slowly vent all line pressure on the 3410 Series Gas Ultrasonic Meter to atmosphere.
Disconnect transducer cable from the transducer holder.
If installed, remove the mount cover by loosening the two mount cover captive
screws.