3.4.2 Manual Mode: "

There are the following variations in the detection function that are available
in the manual mode.
Indication
Normal
Peak hold
Bottom hold
Peak-to-peak hold
Sample hold
Average hold
Reference
For each holding measurement, refer to section "2.3.1 Holding Measure-
ment Function" on page 32.
Setting example
Select peak hold.
<Detection state>
<Application mode>
<Manual mode>
54
" (manual)
Name
The measurement result is displayed and
output whenever necessary.
The maximum value in the designated
interval is measured.
The minimum value in the designated
interval is measured.
The difference between the maximum and
minimum values in the designated interval
is measured.
The momentary value at the designated
timing is measured.
A simple mean of the measurement interval
is measured.
Press
to select "APPLI".
Description of action
Press
to select peak hold.
Set
<Peak hold>