Digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

When a different power supply is used for 2, or more, controllers, be sure
to connect either 0 V lines or +V lines of the controllers each other. Other-
Notice
wise, the transmission by GP-XCOM and the interference prevention func-
tion are not properly operated.
Minimum input time of each terminal input
Zero setting input
Memory switching input 1,2
ON
2.0ms
Output response time
In the case without holding measurement
Averaging frequency
1
2
4
8
16
32
64
128
256
512
1,024
2,048
4,096
8,192
16,384
140
Resetting input
ON
1ms
Output response in respect to timing
Response time
input of holding measurement
0.075
(With a controller operating independently)
0.100
0.150
Timing input
0.250
0.450
0.850
1.650
Analog output
Judgment output
3.250
6.450
12.850
When the BCD unit (GP-XBCD) is used, the
25.650
sampling period becomes double (50μs).
51.250
Therefore, the response time becomes also
102.450
double (Maximum speed: 0.15ms).
204.850
409.650
Timing input (external trigger)
ON
200 s
ON
OFF
Max. 100 s