2 Mechanical Installation
2.
For disconnecting the operator cable, firmly press the tab that is holding the cable in place and then pull out the plug as shown in the figure
below. Disconnect the cable only from the operator at the front cover (cable is fixed to the drive side on size B units)
Main Circuit and Control Circuit Wiring
Note:
Before wiring up the drive, remove the sealing grommets from the access holes in the bottom of the drive. The figure below explains the purpose of each hole. Make
sure the proper holes are used. Do not remove the rubber bushings from holes that will not be used.
NOTICE: Be sure to use the recommended waterproof cable glands for all cables entering and exiting the drive.
NOTICE: RJ45 connector on drives with model code CIMR....-0081 is meant to connect an external digital operator JVOP-180(LCD), JVOP-182(LED) (with recommended
cable, YASKAWA part No. 72606-WV003) or JVOP-181 (USB Copy Unit) for PC connection. Do NOT connect any other device to the RJ45 connector. Otherwise
the drive or external device may be damaged.
1.
After removing the rubber bushings, insert the cable glands into the holes and tighten them with the locknut.
Refer to
Cable Glands Specifications and Model Numbers on page 11
2.
Route the cables through the cable glands, following the instructions in
3.
Tighten the cable gland caps.
EN 10
Power Supply Cable
optional RS485 connector
(CIMR.... -0081 variant)
External earthing connector
Cable Gland
(Body)
Cable
EMC Filter
Terminals
Cable Gland
(Cap)
Remove cable
Connector Release Tab
Control circuit and
option wiring
Motor Cable
for the maximum allowable tightening torque.
Cable Gland
(Locknut)
Cable Glands on page
grounding
of cable shield
YASKAWA Europe TOEP C710606 75B - AC Drive V1000 IP66 - Quick Start Guide