IV.1
Delivery package, transport, storage, maintenance, disposal
Delivery package:— Motor from the 6SM45..100 series
Transport:
Packaging:
Storage:
Maintenance:
Cleaning:
Disposal:
Motor series 6SM45..100
05.2000
— Technical description (documentation), 1 copy per delivery
— Motor package leaflet (short info)
— Climate category 2K3 to EN 50178
—
Transport temperature—25...+70°C, max. 20K/hr change
—
Transport humidity rel. humidity 5% - 95% , no condensation
— only by qualified personnel
— only in the manufacturer's original recyclable packaging
— avoid shocks
— if the packaging is damaged, check the motor for visible damage.
—
Inform the carrier and, if appropriate, the manufacturer.
Motor type
Carton
6SM45
X
6SM56
X
6SM71K/71S
X
6SM71M
6SM100
— Climate category 1K4 to EN 50178
—
Storage temperature
—
Humidity
— only in the manufacturer's original recyclable packaging
— max. stacking height
— Storage time
— Only by qualified personnel
— The ball bearings have a grease packing which is adequate for
—
20,000 hours of operation under normal conditions. The bearings
—
should be replaced after 20,000 hours of operation under rated
—
conditions.
— Check the motor for bearing noise every 2500 operating hours,
—
respectively each year. If any noises are heard, then the operation
—
of the motor must stop, the bearings must be replaced.
— Opening the motor invalidates the warranty.
— If the housing is dirty:
do not immerse or spray
— If a separate fan is fitted: check the fan mesh for dirt twice a year.
—
If necessary, clean the mesh with a brush.
— The disposal should be carried out by a certified disposal company.
—
Ask us for addresses.
Pallet or skeleton box
X
X
—25...+55°C, max. variation 20K/hr.
rel. humidity 5% - 95%, no condensation
see table under Packaging
unlimited
clean with Isopropanol or similar.
Appendix
Max. stacking height
6
6
5
1
1
41