Adaptation To Different Types Of Gas - Smeg PS906 Instructions For Installation And Use Manual

Smeg range instructions for installation and use
Table of Contents

Advertisement

Instructions for the installer

10. ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance
from the electricity supply.
The appliance is tested for natural gas G20 (2H) at a pressure of 20
mbar. In the case of operation with other types of gas the burner nozzles
must be changed and the minimum flame adjusted on the gas taps. To
change the nozzles, proceed as described below.
10.1 Replacement of nozzles on the cooker hob
1 Extract the grids and remove all the caps and flame-spreader crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the burner nozzles according to the type of gas to be used
(see point "10.2 Burner and nozzle characteristics table").
4 Replace the burners in the correct position.
The nozzles for using town gas (G110 – 8 mbar) are available from
authorised service centres.
38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps906-4Psf906Psf906-4

Table of Contents