3-2-6

Serial Command List

A list of the supported Serial commands.
Category
Setting
<Knnn,
change (K
Parameter>
Command)
nnn: Three-
digit number
of each K
command
Execute a
User Defined
Read
(Default: < >)
User Defined
(Default: Dis-
abled)
User Defined
(Default: Dis-
abled)
Read Test
<C>
<Cp>
<J>
Auto-adjust
<@CAL>
Train
<TRAIN>
<UNTRAIN>
<TRAIN?>
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
3 Controlling Operation and Data Output with Ethernet
Command
Commands to change settings on the reader.
Refer to the Auto Focus Multi Code Reader
V430-F Series User Manual (Z392) -
Appendices A-6 to A-17 for additional informa-
tion on K Commands.
Command (Delimited) to execute a Read.
(Reference: Change the Command that
Executes Read on page 3 - 31)
The Start Character (Non-Delimited)
(Reference: Change the Command that
Executes Read on page 3 - 31)
The Stop Character (Non-Delimited)
(Reference: Change the Command that
Executes Read on page 3 - 31)
Tests the number of Decodes per second. The
Response data output is the number of
Decodes per second and the Read character
string.
Tests the Read Rate (%). The Response data
output is the percentage of Good Read per
100 Reads and the Read character string.
Ends the Read test.
Automatically adjusts the settings for
Exposure, Focus Position and Symbol Type.
Calibration PASSED is output as the
Response data from halfway through the
progress and when calibration completes
successfully. If calibration fails, the message,
Calibration FAILED will be output.
Start the Train operation. Trains with the next
Symbol read. When reading the same code
symbols, using Train can make Reading
results more stable.
Release the Train operation.
Verifies the Train status. Depending on the
status of the Train, the Response data will be
one of the following.
<TRAIN,0>: Default, Train not done
<TRAIN,1>: Train in progress
<TRAIN,2>: Training of Symbol complete
Description
Response Data Example
(For Read string ABCDE.)
None
(If the Serial Verification
function is enabled, the
Response data will be the
same as that for the <Knnn?>
command.)
ABCDE
ABCDE
ABCDE
*1
5 Decodes / Sec ABCDE
(By this you can see 5 Good
Read in 1 second)
*1
95% ABCDE
(By this you can see 95 Good
Reads out of 100 Reads.)
None
Prog | Exposure Gain Bright-
ness 2 | 5764 33 24 100 |
6011 33 37 Calibration
*1
PASSED.
None
None
<TRAIN,2>
3 - 41
3