Communication Settings (Ethernet/Ip) - Omron V430-F Series User Manual For Communication Settings

Code reader, auto focus multi code reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

3 Controlling Operation and Data Output with Ethernet
3-1-4

Communication Settings (EtherNet/IP)

Using WebLink to Set the Reader Network Settings
Use WebLink to set the IP address on the reader to match the network settings of the PLC or other
external device.
• WebLink - Setup - Gear Icon - Advanced Settings - Communications - Ethernet
1
Set Ethernet to Enabled.
2
Set the IP Address and Subnet Mask according to the network settings of the PLC or other
external device.
Setting Item
Ethernet
IP Address
Subnet
Gateway
IP Address Mode
3 - 6
Setting Value
Enabled
(Default)
Disabled
a.b.c.d
a: 0 to 255
b: 0 to 255
c: 0 to 255
d: 0 to 255
(Default:
192.168.188.2)
a.b.c.d
a: 0 to 255
b: 0 to 255
c: 0 to 255
d: 0 to 255
(Default:
255.255.0.0)
a.b.c.d
a: 0 to 255
b: 0 to 255
c: 0 to 255
d: 0 to 255
(Default: 0.0.0.0)
Fixed (Default)
DHCP
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Description
Select whether to enable all, some, or none of the various
Ethernet protocols, (Serial (TCP)), EtherNet/IP, PROFINET).
Enter the IP address of the Reader
Input the subnet mask address.
If a Gateway is used, enter the gateway address. If a
Gateway is not used, use the default value 0.0.0.0.
In Fixed mode, the reader uses a user-defined IP address.
In DHCP mode, the reader acquires its IP address, subnet,
and gateway from the DHCP server.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents