1 Communication Specifications Overview
1-1
Confirming the System Configuration
This product is a multicode reader that captures images of 1D symbols (barcodes) and 2D Symbols
and reads and processes their embedded data.
In a system configuration in which it is connected to a PLC, PC, or other external device, serial
commands can be received from, and code reading results can be output to the external device.
1-1-1
V430 Series System Configuration
The V430-F can be used in the following types of system configurations.
Connection using Parallel Interface
Trigger inputs and OK/NG Judgement result outputs are received and sent over I/O cable.
Basic configuration
Reader
*1
*1 If monitor display is not required, it is not necessary to connect with a PC during operation.
Connecting over Ethernet (EtherNet/IP, Serial (TCP), PROFINET)
Establish network connections via an Ethernet cable to input triggers and communication commands
and to output reading results (judgment results and decoded content). Triggers can also be input over
parallel. Using the data link function for each network (excluding Serial), data transfer can be done
periodically between the reader and the external device.
Basic configuration
Reader
Switching hub
for EtherNet/IP
(industrial
Ethernet)
*1
1 - 2
Special Ethernet cable
Computer
WebLink or ESP
Special Ethernet cable
General-purpose
Ethernet cable
General-purpose
Ethernet cable
Computer
WebLink or ESP
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
External devices
Trigger sensor
I/O cable
I/O control PLC
External devices
Trigger sensor
I/O cable