3 Controlling Operation and Data Output with Ethernet
Category
Optimization
3 - 42
Command
<OPT>
Starts Optimization. Optimization using the
next Symbol read. When reading the same
code symbols, using Optimization can make
the Reading speed faster.
<UNOPT>
Releases Optimization.
<OPT?>
Confirm the Optimization status. Depending
on the Optimization status, the Response data
will be one of the following.
<OPT,0>: Default, No Optimization
<OPT,1>: Optimization in Progress
<OPT,2>: Optimization of Symbol is com-
plete
<?>
Gets the hexidecimal number showing the
reader status. Information for error conditions
on the reader and Read Cycle status can be
obtained. For more detailed information,
please refer to Auto Focus Multi Code Reader
V430-F Series User Manual (Z392) -
Appendices A-16 Utilities.
<K?>
Queries the settings status of all K
Commands.
<K??>
Gets the description of all K Command
parameters.
<K?#>
Gets the parameter ranges of all K
Commands.
<Knnn?>
Queries the setting status of the specified K
(nnn: Three-
Command.
digit number
of each K
command)
<Knnn??>
Queries the parameter description of the
(nnn: Three-
specified K Command.
digit number
of each K
command)
<Knnn?#>
Gets the parameter range of the specified K
(nnn: Three-
Command.
digit number
of each K
command)
<Knnn?*>
Gets the same Response data as when the
(nnn: Three-
<Knnn?> command, <Knnn??> command, or
digit number
<Knnn?#> command is executed.
of each K
command)
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Description
Response Data Example
(For Read string ABCDE.)
None
None
<OPT,0>
<?/02>
(You can see there is currently
no error condition on the read-
er.)
Settings status of all K
Commands.
Description of all K Command
parameters.
Parameter ranges of all K
Commands.
<K541,2000,30>
(Example response to
<K541??> Exposure: 2000us,
Gain: 30)
<K541??,Exposure,Gain>
(Example Response data for
<K541??> You can see that
Parameter 1 is Exposure and
Parameter 2 is Gain.)
<K541?#,Value
25-100000:Def=2500,Value
0-100:Def=33>
(Example Response data for
<K541?#> You can see that
the setting range of
Parameter 1 is 25 to 100000
with a default value of 2500,
while the setting range of
Parameter 2 is 0 to 100 with a
default value of 33.)
<K541,2000,30>
<K541??,Exposure,Gain>
<K541?#,Value
25-100000:Def=2500,Value
0-100:Def=33>
(Example Response data for
<K541?*>.)