Using the DEFAULT Signal to Reset the Reader
Used whenever a hardware reset is performed.
• Signal wire to use
Green
Black
In cases where a software reset or hardware reset is not possible, it may be necessary to reset the
reader by short-circuiting (connecting) the two pin types shown above. This will do the same thing
as sending the <Zrdall> command.
Precautions for Correct Use
If a hardware reset is performed in this manner, it must be executed within 60 seconds of the
reader being started by either its power supply being turned on or the reader being reset.
Connecting incorrect pins can cause serious damage to the equipment.
 How to use
1
Verify the location of Pin 3 (DEFAULT) and Pin 7 (GROUND) on the connector.
2
Supplies power to the reader.
3
Indicator light PWR (Green) lights up.
4
After a while, the indicator lights LINK (Orange), MODE (Orange), TRIG (Orange) will light up
once and the reader will start up.
5
Within 60 seconds of this indication of the reader starting up, short-circuit (connect) Pin 3 and
Pin 7.
6
Within 3 seconds after doing that, disconnect and then re-connect Pin 3 and Pin 7 (short-circuit
them again).
7
The reader resets. After it restarts this time, disconnect Pin 3 and Pin 7.
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
2 Controlling Operation and Data Output with Parallel
Color
3
7
Pin No.
DEFAULT
GROUND
Signal
2
2 - 23