3 Controlling Operation and Data Output with Ethernet
Additional Information
When Multiple Symbol Reading is enabled, the Output Order is read character string of symbol
1, additional information for symbol 1, read character string for symbol 2, additional information
for symbol 2, and so on.
3-2-5

Controlling Operation from an External Device

The reader can be controlled, have its settings viewed and changed from an external device with the
use of serial commands.
The V430 serial commands are divided broadly in to two different types.
• Serial Configuration Commands (K Commands):
Commands to change settings on the V430.
• Serial Utility Commands:
Commands used to test Read Rate, get reader status and control automatic adjustments.
Serial Command Format
Explanation of how commands are formatted in Serial communication.
 Common Command Format for Serial Configuration Commands and Serial
Utility Commands
• Enclose the commands in brackets "< >".
• Characters used in commands and data are case-sensitive. Use either upper-case, or lower-
case characters as required.
• Serial commands can be linked together in a chain. For example, the following command sets
Trigger Mode to External Trigger/Edge, sets the End of Read Cycle condition to New Trigger, and
saves the setting.
<K200,3> <K220,1> <Z>
 Serial Configuration Command (K Commands) Format
• The K Commands consist of the letter K, followed by a three digit number and comma-separated
parameters as shown below.
<
K
Separator
• Some K Commands can change multiple parameters. For those, if the final parameter does not
need to be changed, it can be omitted.
For example, when using the K Command <K541> which is used for changing both Exposure
time and Gain, if you only need to change the Exposure time, it can be entered as follows.
<K541,1000>
• If the parameter that does not need to be changed is not the last in sequence, only the comma
delimiter for it is necessary.
For example, when using the K Command <K541> which is used for changing both Exposure
time and Gain, if you only need to change the Gain, it can be entered as follows.
<K541,,30>
3 - 38
Command
Parameter1
5
4
0
1
,
2
Comma
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Parameter2
0
0
,
3
0
>
Comma
Separator