Omron V430-F Series User Manual For Communication Settings page 114

Code reader, auto focus multi code reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

Appendices
DECODE DATA
Member Description
• INFO BITS
- Same structure as MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• Configuration Change Detection
- Same structure as MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• Device Status
- Same structure as MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• Error Code
- Same structure as MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• Counters
- Same structure as MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• ReadCycle Report
- Same structure as MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• Same as Decode 4 Cycle Report
- Same structure as MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• Decode Length
Stores the number of characters in the Read string.
• Decode Data
Stores the Read string. When additional information such as a Symbol Quality Grading Standard is
set, it is stored following the Read string.
Assembly Memory Allocation
32 bit
A - 16
Member Name
Member Name
InfoBits
Bit Run Mode
Bit Connection Faulted
Reserved
Reserved
Reserved
Configuration Change De-
tect
Config Change Detect
Reserved
Reserved
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
436
Data Type
Bit Number
SINT
0
1
2
3 - 7
SINT
SINT
0
1 - 7
Size (Bytes)
Total Size: 500 Bytes
Data Length
Byte Offset
1 Byte
0
1 bit
1 bit
1 bit
5 bit
1 Byte
1
1 Byte
2
1 bit
7 bit
1 byte
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents