Omron V430-F Series User Manual For Communication Settings page 107

Code reader, auto focus multi code reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

DECODE CYCLE REPORT
DECODE LENGTH
DECODE DATA
Member Description
• INFO BITS
Bit
0
1
2 - 7
• Configuration Change Detection
This bit is set to 1 if any configuration changes are made to the reader after connecting.
If the setting is returned to the original state, 0 is set.
• Device Status
Shows the current status of the reader.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22 - 30
・Run Mode
Shows Read Cycle Enabled/Disabled status.
0 = Read Cycle Disabled Cannot accept Trigger. However, it can receive a command.
1 = Read Cycle Enabled State in which trigger can be accepted.
・Trigger Acknowledged
V430-F Series Auto Focus Multi Code Reader User Manual for Communication Settings (Z407-E1)
Member Name
State
Run Mode
Connection Faulted
Reserved
Bit
Run Mode
Trigger Acknowledged
Exposure Done
Decoding
Data Is Ready
Read Cycle Pass
Read Cycle Fail
General Fault
New Match Code Acknowledged
Match Code Enabled
Image Sensor Calibrating
Image Sensor Calibration Complete
Training
Training Complete
Optimizing
Optimization Complete
AutoImage Photometry Enabled
AutoImage Photometry Complete
Output 1 Status
Output 2 Status
Output 3 Status
Buffer Overflow
Reserved
16
4
184
Description
Is 1 when Read Cycle is enabled.
Always 0 while connected.
State
Appendices
Size (Bytes)
Total Size: 248 Bytes
A - 9
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents