System Configuration - Omron FQ-CR1 User Manual

Fixed mount multi code reader
Hide thumbs Also See for FQ-CR1:
Table of Contents

Advertisement

2-1 System Configuration

Parallel Interface Connection
Setup Tool
Touch Finder or PC Tool
Connecting to Ethernet
Setup Tool
Touch Finder or PC Tool
Multiple Connection Sensors
Setup Tool
Touch Finder
or PC Tool
Product
Model number
FQ-CR1 Sensor
FQ-CR1@@@@@
Touch Finder
FQ-D@@
PC Tool
---
FQ Ethernet Cable
FQ-WN0@@
Standard RJ45
---
*1
Ethernet Cable
I/O Cable
FQ-WD0@@
Switching Hub
W4S1-0@@
*1: The shape and dimensions of the Ethernet connector plug and jack are specified in ISO/IEC8877:1992 (JIS X 5110:1996) and RJ-45 of the
FCC regulations. To prevent connector connection failures, the structure of the jack of this product does not allow insertion of plugs that do not
comply with the standard. If a commercially available plug cannot be inserted, it is likely that the plug is non-compliant.
Important
Do not connect network devices other than PLCs on the same network as the Touch Finder or computer. If
another device is connected, the responsiveness of displays and settings of the Touch Finder or computer may
become slow.
18

System Configuration

FQ-CR1 Sensor
FQ Ethernet Cable
24-VDC power supply
Switching Hub
Standard RJ45
Ethernet Cable
24-VDC power
supply
Standard RJ45
Ethernet Cable
Switching Hub
Switching Hub
Standard RJ45
Ethernet Cable
Standard RJ45 Ethernet Cable
Remarks
This is the Sensor.
This is a setup console. (Software version must be 1.3 or higher)
The PC Tool can be used instead of the Touch Finder. (Software version must be 1.3 or
higher) If you register as a member, you can download the free PC Tool as a special ser-
vice to purchasers.
Refer to the Member Registration Sheet that is enclosed with the Sensor for the member
registration procedure and the download procedure for special member software.
Connects the Sensors to external devices such as the Touch Finder, computers, and PLCs.
Connects the Switching Hub to the Touch Finder, computers, and PLCs. Use a connector
that complies with the FCC RJ45 standard. (STP (shielded twisted-pair) cable, category 5e
or 6, impedance: 100 )
Connects the Sensor to the power supply and external devices.
Used to connect multiple Sensors to one Touch Finder or PC Tool.
I/O Cable
24-VDC power
supply
Standard RJ45 Ethernet Cable
FQ-CR1
Sensor
I/O Cable
FQ-CR1 Sensor
FQ Ethernet Cable
Standard RJ45 Ethernet Cable
Trigger Sensor
PLC
PLC to control Sensor
24-VDC power
supply
FQ Ethernet Cable
Switching Hub
FQ User's Manual