Maintenance; Maintenance Run; Relubricating; Cleaning - PI L-412.039211E0 User Manual

High-load linear stage
Table of Contents

Advertisement

8 MAINTENANCE

8
Maintenance
NOTICE
Damage due to improper maintenance!
Improper maintenance can lead to misalignment and failure of the L-412.xx9211E0.
► Loosen screws only according to the instructions in this manual or the instructions of our
customer service department (p.
8.1

Maintenance Run

The maintenance run serves the purpose of distributing the existing lubricant.
The following intervals for the maintenance run depend on the operating conditions and the
period of use:
■ After 200 operating hours or at least after one 1 year
■ If the L-412.xx9211E0 is moved over a small travel range (<40 mm) during industrial
operation: After every 2000 motion cycles
Performing a Maintenance Run
1. Make sure that collisions between the L-412.xx9211E0, the load to be moved, and the
surroundings are not possible over the entire travel range of the L-412.xx9211E0. If
necessary, remove the load from the motion platform of the L-412.xx9211E0 for the
maintenance run.
2. Perform a maintenance run over the entire travel range:
a) Command the L-412.xx9211E0 to the end of a travel range and from there to the
opposite end of the travel range (see manual for the electronics).
b) If necessary: Command the L-412.xx9211E0 to a position, where the load can be
mounted onto the motion platform again and
L-412.xx9211E0 (p.
8.2

Relubricating

The L-412.xx9211E0 is equipped with a grease nipple for relubricating the drive screw. For
continuous industrial use, the lubrication intervals and the lubrication quantity must be
determined individually.
Use Klüber STABURAGS NBU 12/300 KP only as lubrication for the L-412.xx9211E0.
If you have any questions on relubricating, contact our
8.3

Cleaning

Requirements
You have disconnected the L-412.xx9211E0 from the electronics.
Other Materials Required
■ Soft, lint-free cloth
■ Mild cleaning agent or disinfectant
If you have any questions on the auxiliary materials recommended for the L-412.xx9211E0,
contact our
22
L412M0016EN ‒ 3/14/2019
17).
customer service department (p.
26).
mount the load back onto the
customer service department (p.
26).
26).
M O T I O N | P O S I T I O N I N G

Advertisement

Table of Contents
loading

Table of Contents