12 TECHNICAL DATA
Miscellaneous
Operating temperature range 5 to 40
Material
Overall mass
Moved mass
MTBF
Connector
Limit switch connection
Purge air system
Recommended controllers
Connecting cables are not in the scope of delivery and must be ordered separately.
12.2

Maximum Ratings

The L-412.xx9211E0 is designed for the following operating data:
Maximum operating voltage Maximum operating fre-
320 V
12.3

Ambient Conditions and Classifications

The following ambient conditions and classifications for the L-412.xx9211E0 must be
observed:
30
L412M0016EN ‒ 3/14/2019
L-412
Aluminum, black anodized
stainless steel
L-412.03 (52 mm travel range): 6.4
L-412.05 (102 mm travel range): 6.9
L-412.09 (204 mm travel range): 7.9
L-412.13 (305 mm travel range): 8.9
L-412.17 (407 mm travel range): 9.8
L-412.21 (508 mm travel range): 10.8
L-412.25 (610 mm travel range): 11.8
1.4
20000
M23 (motor)
M23 (rotary encoder)
Optional connection for linear encoder
Fitting for purge air hose with outside diame-
ter 4 mm
Funnel-type grease nipple for drive screw lu-
brication
M8 8-pin
Operating pressure: 2 to 6 bar (200 to 600
kPa)
Relative humidity: < 70 %
Absolute humidity: < 35 g/m
ACS modular controller
quency
Unit
°C
kg
kg
h
3
Maximum peak current, RMS
10.9 A
M O T I O N | P O S I T I O N I N G
Toler-
ance
±5 %
±5 %

Advertisement